M-AUDIO 2626 ユーザーズマニュアル

ページ / 51
User Guide
27
ProFire 2626
Mixer Peak Meters
This section of the Control Panel configures the operation of the meters within the DSP Mixer 
Mode
 
This drop-down menu determines the behavior of the meters of the ProFire 2626 DSP mixer   
 
 
 Pre-fader – When this parameter is set to “Pre-fader” the meters will display the level of a signal before it 
passes the fader   This allows signal levels to be displayed regardless of the fader positions within the DSP 
mixer (i e , a fader can be all the way down and no sound will be heard from the mixer’s output, but you can 
still see if there is any activity on that input)   
 
 
 Post-fader – This setting configures the meters to show levels after signal has passed through the faders   
In this configuration, fader positions will affect the meters   For example, a fader that is all the way down will 
result in no signal being displayed on its meter 
Peak Hold
 
 The meters of the ProFire 2626 DSP mixer feature a “peak hold” 
function designed to assist in finding the loudest transients of 
a signal   This drop-down menu determines how long the peak 
indicator will remain before resetting:
Off
This setting turns the peak hold function off
1 Second
Peak levels are held for one second
3 Seconds
Peak levels are held for three seconds
Infinite
Peak levels are held until the meters are cleared
Standalone Mode
 ProFire 2626 can be used in Standalone Mode (i e , without a computer)   To enter Standalone Mode, power down 
the interface, disconnect any FireWire cables attached to the FireWire Ports (12), and power on the interface 
 The parameters in this section of the Control Panel determine how ProFire 2626 will function while operating in 
Standalone Mode   This is a useful feature as it allows you to set the Standalone Mode settings independently from 
the hosted settings   This saves you from having to reconfigure the Control Panel each time before you use the 
interface in Standalone Mode 
Sync Source
 
 This drop-down menu determines the clock synchronization source when using ProFire 2626 in Standalone 
Mode   
 
  If you have connected a S/PDIF, ADAT, or Word Clock device to your ProFire 2626 and would like to use that 
device’s clock as the master clock source, select “ADAT A,” “ADAT B,” “Coax S/PDIF,” or “Word Clock” from 
this drop down menu   Otherwise, leave this parameter on its default “Internal” setting to allow ProFire 2626 to 
use its internal clock 
TIP:  Peak levels can be cleared at 
any time by clicking the meters in the 
DSP mixer.