(b) Auto refresh setting
Set devices storing the present values, latch count values, overflow detection 
flags, error codes, and warning codes of CH1 and CH2.
For Auto refresh setting in GX Configurator-CT, refer to Section 6.5.
Figure 7.5 Auto refresh setting screen
Table 7.3 Item on the [Initial setting] screen
Setting item
Description
Setting
CH1 Initial setting
Preset value setting
Set preset value.
0
Coincidence output 
No.1 point setting
Set these only when 
the counter value 
comparison function 
selection (refer to 
Section 4.5) is the 
coincidence output 
function.
10000
Coincidence output 
No.1 point change 
request
Change request
CH2 Initial setting
Ring counter lower limit 
value
Set these only when 
using the ring counter 
function.
-50000
Ring counter upper limit 
value
50000
Preset value setting
Set preset value.
-50000
CH2 continuous 
comparison No.1 setting
Continuous comparison 
No.1 start point setting
Set these only when 
the counter value 
comparison function 
selection (refer to 
Section 4.5) is the 
continuous comparison 
function.
1
Continuous comparison 
No.1 repeat point 
setting
2
Continuous comparison 
No.1 ON time setting
10
Continuous comparison 
No.1 point 1 setting
20000
Continuous comparison 
No.1 point 2 setting
40000