Mitsubishi Electronics QD64D2 ユーザーズマニュアル

ページ / 154
3
 - 20
3.4 Buffer Memory Assignment
3.4.2 Details of the buffer memory
3
SPECIFICATIONS
(3) Coincidence output No.1 point setting (Un\G6 and 7)
Coincidence output No.1 point change request (Un\G10)
Coincidence output No.2 point setting (Un\G8 and 9)
Coincidence output No.2 point change request (Un\G11)
 • This area is used for setting the comparison point (the value used to compare 
with the present value) used for the coincidence output function.
 • Setting procedure
1) Write any comparison point to the coincidence output No.1 point setting (Un\G 
6 and 7).
Setting range: -2147483648 to 2147483647
2) Write "1" (Change request) to the coincidence output No.1 point change 
request (Un\G10).
3) The comparison point written to the coincidence output No.1 point setting 
(Un\G6 and 7) becomes effective, and the coincidence output No.1 point 
change request (Un\G10) changes from "1" to "0" (No change request).
4) The comparison between the set comparison point and the present value is 
executed.
 • The above procedure is described as an example of the coincidence output No.1. 
To set the coincidence output No.2, replace the coincidence output No.1 setting 
(Un\G6 and 7) and the coincidence output No.1 point change request (Un\G10) 
with the coincidence output No.2 point setting (Un\G8 and 9) and the coincidence 
output No.2 point change request (Un\G11).
Figure 3.20 Timing chart for the coincidence output No.1 point setting (Un\G6 and 7) and the coincidence output No.1 point change 
request (Un\G10)
 • For details of the operation, refer to Section 5.3.1.
Note) If a value other than "1" is written to the coincidence output No.1 point
change request, the comparison point written to the coincidence output No.1
point setting does not become effective. 
For the comparison point, a value previously set in the coincidence output
No.1 point setting is used.  
For example, the default value of the coincidence output No.1 point setting is
"0". If "10000" is written to the coincidence output No.1 point setting, the
default value of "0" is used for the comparison point unless "1" is written to
the coincidence output No.1 point change request.  
200
100
*1
0
0
0
1
0
*1
1
Operation by the QD64D2
Coincidence output No.1 point change request 
(Un\G10)
Coincidence output No.1 point 1 setting 
(Un\G6 and 7)
*1 When the coincidence output No.1 point setting (Un\G6 and 7) becomes 
effective, the QD64D2 writes "0" to the coincidence output No.1 point change 
request (Un\G10).