Oregon Scientific BAR210 プリント

ページ / 2
Weather Light
Model: BAR210 / BAR210U / BAR210A
USER MANUAL
EN
OVERVIEW
LCD DISPLAY 
1
2
3
4
5
6
1.  Weather forecast icons
2.  Clock signal reception indicator
3.  Time / temperature display
4.  Outdoor sensor communication indicator
5.  Low battery indicator
6.  Time zone offset display
BACK VIEW
1
2
1.  Ventilation hole
2.  Adaptor socket
BOTTOM VIEW 
1
2
3
4
5
6
1
  / 
:  Increase  /  decrease  setting;  activate  / 
deactivate clock reception signal
2.  RESET: Reset unit to default settings
3.  AUTO ON / OFF: Select auto toggle mode
4.  CLOCK: Set time and display mode
5.  °C / °F: Select temperature unit and display mode
6.  Battery compartment
REMOTE SENSOR 
           
1.  LED status indicator
2.  Wall mount hole
3.  Battery compartment 
4.  RESET hole 
5.  CHANNEL switch
GETTING STARTED
POWER SUPPLY
Batteries  serve  as  back  up  power  supply  for  the  clock.   
For  continuous  use  of  LCD  backlight,  always  plug  in  the 
adapter  socket.    Make  sure  the  socket  outlet  is  easily 
accessible to the unit.
To insert batteries:
1.  Remove  the  battery  compartment  and  insert  the 
batteries, matching the polarities.
2.  Press RESET after each battery change.
 indicates main unit batteries are low.
REMOTE SENSOR
The main unit can be connected to only 1 remote sensor.
To set up the outside sensor:
1.  Open the battery compartment. 
2.  Select a channel then press RESET
3.  Close the battery door.
4.  Place the outside sensor within 30 m (98 ft) of the main 
unit using the table stand or wall mount.
TIP The transmission range may vary depending on many 
factors. You may need to experiment with various locations 
to get the best results.
NOTE  Use  alkaline  batteries  for  longer  usage  and 
consumer  grade  lithium  batteries  in  temperatures  below 
freezing.
SENSOR DATA TRANSMISSION
The  main  unit  will  automatically  search  for  the  outdoor 
sensor.  The  sensor  reception  icon  in  the  remote  sensor 
area shows the status:
ICON
DESCRIPTION
Main unit is searching for 
sensor.
A channel has been found.
Sensor data received.
 and “--.-
The sensor cannot be 
found. 
NOTE  If  the  sensor  is  not  found,  check  the  batteries, 
obstructions and remote sensor location. 
For best results:
•  Place the sensor out of direct sunlight and rain.
•  Position  the  sensor  facing  the  main  unit,  minimizing 
obstructions.
•  Place  the  sensor  in  a  location  away  from  metallic  or 
electronic objects.
•  Position  the  sensor  close  to  the  main  unit  during  cold 
winter months.
CLOCK 
CLOCK RECEPTION
This  product  is  designed  to  synchronize  its  clock 
automatically with a clock signal.
BAR210:
•  EU:  DCF-77  signal:  within  1500  km  (932  miles)  of 
Frankfurt, Germany.
BAR210U:
•  UK:  MSF-60  signal:  within  1500  km  (932  miles)  of 
Anthorn, England.
BAR210A:
•  WWVB-60  signal:  within  3200km  (2000  miles)  of  Fort 
Collins Colorado.
To enable / disable signal reception:
Press  and  hold 
  to  enable  or 
  to  disable  signal 
reception.
NOTE Reception takes 2-10 minutes. If the signal is weak, 
it can take up to 24 hours to get a valid signal.
 
Clock signal reception indicator:
STRONG 
SIGNAL
WEAK SIGNAL
NO SIGNAL
SET CLOCK
To  set  the  clock  manually,  disable  the  signal  reception 
fi rst.
1.  Press and hold CLOCK.
2.  Press 
 or 
 to change the settings.
3.  Press CLOCK to confi rm.
4.  The settings order is: time zone offset, 12/24 hr format, 
hour and minute.
BAR210 / BAR210U: Time zone offset sets the clock +/- 
23 hours from the received clock signal time.  If you have 
deactivated the clock signal reception, do not set a value 
for time zone offset.
BAR210A: Select the time zone: (P) Pacifi c, (E) Eastern, 
(C) Central or (M) Mountain.
CHANGE DISPLAY
•  To change to auto toggle mode (clock > outdoor tem-
perature > indoor temperature), slide AUTO ON / OFF 
to ON.
•  To  manually  toggle  between  time  and  temperature 
displays, press CLOCK or wave your hand at least 3 
inches or less from the motion sensor located on the 
top of the main unit.
NOTE  Auto  toggle  mode  and  motion  sensor  will  be 
disabled if a button is pressed, but will be enabled again if 
no button is pressed for 5 seconds.
NOTE The installed CDS light sensor inside the unit will 
activate automatic LCD dimming.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather.
 
ICON
COLOR
 Red
 Green
 Blue
MEANING
Sunny
Cloudy
Rainy
TEMPERATURE
To  display  temperature  mode  or  select  temperature 
unit:
Press °C / °F.
NOTE Please keep the temperature sensor (adjacent to 
the adaptor socket) away from electrical devices as heat 
from these devices will affect accurate indoor temperature 
readings.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
•  Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.
•  Do not cover the ventilation hole with any items such 
as newspapers, curtains etc.
•  Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.
•  Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 
•  Do not tamper with the unit’s internal components. This 
invalidates the warranty.
•  Only  use  fresh  batteries.  Do  not  mix  new  and  old 
batteries.
•  Images shown in this manual may differ from the actual 
display.
•  When disposing of this product, ensure it is collected 
separately for special treatment.
•  Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  fi nish  for  which  Oregon 
Scientifi c will not be responsible. Consult the furniture 
manufacturer's care instructions for information.
•  The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.
•  Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection of such waste separately for special 
treatment is necessary.
•  Please  note  that  some  units  are  equipped  with  a 
battery safety strip. Remove the strip from the battery 
compartment before fi rst use.
NOTE The technical specifi cations for this product and the 
contents of the user manual are subject to change without 
notice.
SPECIFICATIONS
TYPE
DESCRIPTION
MAIN UNIT
L x W x H
70 x 80 x 206 mm 
(2.76 x 2.76 x 8.11 in)
Weight
235 g (8.3 oz) 
without battery
Indoor Temperature range
-5°C to 50°C
 (23°F to 122°F)
Outdoor Temperature 
range
-30°C to 50°C
 (-22°F to 122°F)
Resolution
0.1°C (0.2°F)
Signal frequency 
433 MHz
Power
2 x CR2032 batteries
AC / DC adapter
REMOTE UNIT (THN132N)
L x W x H
92 x 60 x 20 mm 
(3.6 x 2.4 x 0.8 in)
Weight
62 g (2.22 ounces)
Transmission range
30 m (98 ft) unobstructed
Temperature range
-40°C to 60°C
 (-40°F to 140°F)
Power
1 x UM-4 (AAA) 1.5 V 
batteries
ABOUT OREGON SCIENTIFIC
Visit  our  website  (www.oregonscientifi c.com)  to  learn 
more about Oregon Scientifi c products. If you’re in the US 
and would like to contact our Customer Care department 
directly,  please  visit:  www2.oregonscientifi c.com/service/
support 
OR 
Call 1-800-853-8883. 
For international inquiries, please visit: 
www2.oregonscientifi c.com/about/international
FCC STATEMENT
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
WARNING  Changes  or  modifi cations  not  expressly 
approved  by  the  party  responsible  for  compliance  could 
void the user’s authority to operate the equipment.
NOTE  This  equipment  has  been  tested  and  found  to 
comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference 
in a residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in 
accordance  with  the  instructions,  may  cause  harmful 
interference  to  radio  communications.  However,  there 
is  no  guarantee  that  interference  will  not  occur  in  a 
particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or 
more of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase  the  separation  between  the  equipment  and 
receiver.
•  Connect  the  equipment  into  an  outlet  on  a  circuit  different 
from that to which the receiver is connected.
•  Consult the dealer or an experienced radio / TV technician 
for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for 
support or sales. Please call our customer service number 
(listed  on  our  website  at  www.oregonscientifi c.com  or  on 
the warranty card for this product) for all inquiries instead.
We
Name: 
 
Oregon Scientifi c, Inc.
Address:   
19861 SW 95
th
 Ave.,Tualatin,
   
 
Oregon 97062 USA
Telephone No.: 
1-800-853-8883
declare that the product 
Product No.: 
BAR210 / BAR210U / BAR210A
Product Name: 
Weather Light
Manufacturer: 
IDT Technology Limited
Address:                     Block C, 9/F, Kaiser Estate,
                                    Phase 1,41 Man Yue St.,     
   
                   Hung Hom, Kowloon, 
   
                   Hong Kong
is in conformity with Part 15 of the FCC Rules.  Operation 
is subject to the following two conditions: 1) This device 
may not cause harmful interference. 2) This device must 
accept  any  interference  received,  including  interference 
that may cause undesired operation.
Station Météo Design
Modèle:BAR210 / BAR210U / BAR210A
MANUEL DE L’UTILISATEUR
FR
VUE D’ENSEMBLE
ECRAN LCD 
1
2
3
4
5
6
1.  Icônes de prévisions météo
2.  Indicateur de réception du signal de l’horloge 
3.  Affi chage de l’heure et de la température 
4.  Indicateur de communication du capteur extérieur
5.  Indicateur de faiblesse des piles
6.  Affi chage du fuseau horaire
FACE ARRIÈRE 
1
2
1.  Trous de ventilation
2.  Prise de l’adaptateur
VUE DU BAS 
1
2
3
4
5
6
1. 
  / 
:  Augmente  /  diminue  les  réglages  ;  active  / 
désactive le signal de réception de l’horloge
2.  RESET (REINITIALISER) :   Réinitialise l’appareil aux 
réglages par défaut
3.  AUTO  ON  /  OFF:  Sélectionne  le  mode  d’alternance 
automatique
4.  CLOCK : Règle l’heure et le mode d’affi chage 
5.  °C / °F: Sélectionne l’unité de température et le mode 
d’affi chage 
6.  Compartiment des piles
SONDE SANS FIL
    
1.  Indicateur LED 
2.  Trou de fi xation murale
3.  Compartiment des piles
4.  Fente RESET (Réinitialiser) 
5.  Bouton CHANNEL (Canal)
POUR COMMENCER 
Les  piles  n’ont  qu’une  fonction  d’alimentation  de  secours 
pour  l’horloge.      Si  vous  désirez  utiliser  continuellement 
le  rétro  éclairage  de  l’écran  LCD,  veuillez  brancher 
l’adaptateur  secteur.      Assurez-vous  que  la  prise  soit 
facilement accessible.
Insérer les piles : 
1.  Ouvrez le compartiment des piles et insérez les piles en 
respectant les polarités (+/-).
2.  Appuyez sur  RESET (REINITIALISER) après chaque 
changement de piles.
  indique  que  les  piles  de  l’appareil  principal  sont 
faibles.
SONDE SANS FIL 
La sonde transmet les informations à la station principale.
Installation du capteur extérieur :
1.  Ouvrez le compartiment des piles. 
2.  Sélectionnez un canal puis appuyez sur RESET. 
3.  Fermez  le couvercle du compartiment des piles.
4.  Installez  le  capteur  extérieur  à  30  m  maximum  (98 
pieds)  de  l’appareil  principal  à  l’aide  du  support  de 
table ou de la fi xation murale. 
ASTUCE  La  gamme  de  transmission  peut  varier  en 
fonction de plusieurs facteurs. Vous pouvez expérimenter 
plusieurs  emplacements  afi n  d’obtenir  les  meilleurs 
résultats possibles.
REMARQUE  Utilisez des piles alcalines pour un usage 
prolongé et des piles au lithium pour la consommation lors 
de températures inférieures au gel. 
TRANSMISSION DES DONNÉES DU CAPTEUR
L’appareil principal recherchera immédiatement le capteur 
extérieur.    L’icône  de  réception  du  capteur  situé  sur  la 
zone  du  capteur  à  distance  vous  indique  le  statut  de  la 
transmission : 
ICONE
DESCRIPTION
Appareil principal à la 
recherche du capteur.
Un canal a été trouvé.
Les données du capteur 
sont en cours de 
réception.
 et ‘’-- :-‘’ 
Le capteur est 
introuvable. 
REMARQUE  Si  le  capteur  n’est  pas  localisé,  vérifi ez 
les  piles,  les  obstructions  possibles  et  l’emplacement  du 
capteur à distance.  
Pour obtenir de meilleurs résultats :
•  Ne placez pas le capteur directement face aux rayons 
du soleil ou en contact avec des matières humides.
•  Installez  le  capteur  face  à  l’appareil  principal  en 
réduisant les obstructions possibles. 
•  Placez le capteur directement vers le ciel, éloigné des 
objets métalliques et électroniques.
•  Installez  le  capteur  à  proximité  de  l’appareil  principal 
pendant les périodes froides de l’hiver. 
HORLOGE
RÉCEPTION DE L’HORLOGE
Ce produit est conçu pour synchroniser automatiquement 
l’horloge avec le signal radio.
BAR210 :
•  EU : Signal DCF-77 : dans un rayon de 1500 Km (932 
miles) depuis Frankfort, Allemagne.
BAR210U:
•  UK : Signal MSF-60 : dans un rayon de 1500 Km (932 
BAR210 USA IM R3.indd   1
9/18/07   10:29:58 AM