RAINFALL
to view the recorded rainfall of the current hour or 
last 24 hours:
.  Press SELECt to navigate to the UVI / Barometer / 
Rainfall Area.    will show next to the Area.
2.  Press ModE repeatedly to select Rainfall display.
3.  Press  MAX  /  MIN  repeatedly  to  toggle  between 
current hour or past 24 hour rainfall.
BACkLIGHt
Press LIGHt to activate the backlight for 5 seconds.
RESEt
Press RESEt to return to the default settings.
SPECIFICAtIoNS
BASE StAtIoN
Dimensions
(L x W x H)
80mm x 0mm x 47mm
(7. x  4.3 x  .9 inches)
Weight
286g (0 ounces) without battery
Battery
6V adaptor; 4 x UM-3 (AA) .5V
USB CoMMUNICAtIoNS HUB
Dimensions
(L x W x H)
68 x 46 x 36 mm
(2.7 x .8 x 5.4 inches)
Weight
02 g (3.6 oz) 
INdooR BARoMEtER
Barometer unit
mb, inHg and mmHg
Measuring range 700 – 050mb/hPa
Accuracy 
+/- 0 mb/hPa
Altitude setting
Sea level
User setting for compensation
Weather display 
Sunny, Partly Cloudy, Cloudy, Rainy 
and Snowy
Memory
Historical data and bar chart for last 
24hrs
INdooR tEMPERAtURE
Temp. unit
°C / °F
Displayed range
0°C to 50°C (32°F to 22°F)
Operating range
-30°C to 60°C (-4°F to 40°F)
Accuracy
0°C - 40°C: +/- °C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Memory
Current, Min and Max temp.
Dew Point w/ Min and Max
INdooR RELAtIVE HUMIdItY
Displayed range
2% to 98%
Operating range
25% to 90%
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Memory
Current, Min and Max
RAdIo-CoNtRoLLEd / AtoMIC CLoCk
Synchronization
Auto or disabled
Clock display
HH:MM:SS
Hour format
2hr AM/PM or 24hr
Calendar
DD/MM or MM/DD
Weekday in 6 
languages
(E, D, F, I, S, R)
REMotE WINd SENSoR UNIt
Dimensions
(L x W x H)
78 x 76 x 24 mm
(7 x 3 x 8.4 inches)
Weight
00 g (3.53 ounces) without battery
Wind speed unit
m/s, kph, mph, knots
Speed accuracy
2 m/s ~ 0 m/s (+/- 3 m/s)
0 m/s ~ 56 m/s (+/- 0%)
Direction 
accuracy
6 positions
Transmission of 
wind speed 
signal
Approx. every 56 seconds
Memory
Max wind speed
Battery 
2 x UM-3 (AA) .5V batteries
oUtdooR tEMPERAtURE / HUMIdItY UNIt
Dimensions
(L x W x H)
5 x 87 x 8 mm
(4.5 x 3.4 x 4.6 inches)
Weight
30 g (4.59 oz) without battery
Humidity range
5% to 95%
Humidity 
accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Temp. unit 
°C / °F
Temperature 
outdoor range 
-30°C to 60°C (-22°F to 40°F)
Temperature 
accuracy
-20°C to 0°C: 
+/- 2.0°C (+/- 4.0°F)
0°C to 40°C: 
+/- .0°C (+/- 2.0°F)
40°C to 50°C: 
+/- 2.0°C (+/- 4.0°F)
50°C to 60°C: 
+/- 3.0°C (+/- 6.0°F)
RF frequency
433 MHz
Range
Up to 00 meters (328 feet) with no 
obstructions
Transmission
Approx. every 02 seconds
Channel no.
3
Batteries
2 x UM-4 (AAA) .5V
 
REMotE RAIN GAUGE
Dimensions
(L x W x H)
4 x 4 x 45 mm
(4.5 x 4.5 x 5.7 inches)
Weight
24 g (8.5 oz) without battery
Rainfall unit
Mm and in
Range
0 mm – 9999 mm
Accuracy
< 5 mm: +/-  mm
5 mm to 9999 mm: +/- 7%
Memory
Past 24hrs, hourly from last memory 
reset
Battery
2 x UM-3 (AA) .5V