Oregon Scientific BAR686A プリント

ページ / 2
INTRODUCTION
Thank you for selecting this Oregon Scientific
TM
 Wireless 
Weather  Forecaster  with  Temperature  Display  and  Self 
- Setting Atomic Clock (BAR686A). This clock is supplied 
with a remote sensor (THN122N) and can support up to 3 
sensors in total (additional sensors sold separately). 
NOTE  Please keep this manual handy as you use your 
new product. It contains practical step-by-step instructions, 
as well as technical specifications and warnings you should 
know about.
CLOCK OVERVIEW
 FRONT VIEW
1. SNOOZE
 BACK VIEW
1. 
 /   : Increase / decrease setting; activate / deactivate 
clock reception signal
2.   CHANNEL: Switch remote sensor display
3.   MODE: Change settings / display
4.   ALARM: View alarm status; set alarm
5.   Battery compartment
6.   TEMP HI / LO   : Change settings or enable / disable 
hi or lo temperature alarm for channel 1 
7.   °C / °F: Select temperature unit
8.   MEM:  View  current,  maximum  and  minimum 
temperature / humidity
9.   RESET: Reset unit to default settings
 LCD DISPLAY
1.   Sensor battery low
2.   Ice warning is active
3.   Pressure trend
4.   Weather Forecast
5.   Alarm set
6.   AM / PM mode selected
7.   Clock signal reception
8.   Clock
9.   Sensor reception icon
10. Hi / lo temperature alarm
11. Outdoor temperature trend
12. Outdoor temperature
13. Max / Min icon
14. Main unit battery low
15. Indoor temperature trend
16. Indoor temperature
17. Max / Min icon
18. Main unit sensor icon
19. Alarm mode
20. Moon Phase
21. Day and Month display
 REMOTE SENSOR (THN122N)
1.   LED  status  indicator: 
Blinks red during data 
transmission
2.   Ventilation duct
1. Wall mount hole
2. RESET hole 
3. CHANNEL switch
4. Battery compartment
GETTING STARTED
 SETTING UP THE CLOCK
Insert batteries before first use, matching the polarity (+ 
and -). RESET after each battery change.
 SENSOR DATA TRANSMISSION
 indicates main unit batteries are low.
NOTE Do not use rechargeable batteries. We recommend 
that you use alkaline batteries with this product for longer 
usage  and  lithium  batteries  in  temperatures  below 
freezing.
REMOTE SENSOR
3.  Select a channel. Make sure you use a different channel 
for each sensor.
4.  Place the sensor near the main unit. Press RESET on 
the sensor. 
5.  Simultaneously press CHANNEL and MEM on the main 
unit to initiate signal sending between the sensor and 
main unit.
6.  Close the battery door and secure the screws.
7.  Place the sensor in the desired location using the table 
stand or wall mount.
For best results:
•   Place the sensor out of direct sunlight and moisture. 
•   Do not place the sensor more than 30 m (100 ft) from 
the main (indoor) unit.
•   Position the sensor so that it faces the main (indoor) 
unit, minimizing obstructions such as doors, walls, and 
furniture.
•   Place the sensor in a location with a clear view to the 
sky, away from metallic or electronic objects.
•   Position the sensor close to the main unit during cold 
winter  months  as  below-freezing  temperatures  may 
affect battery performance and signal transmission. 
The  transmission  range  may  vary  depending  on  many 
factors. You may need to experiment with various locations 
to get the best results.
Standard Alkaline batteries contain significant amounts of 
water. Because of this they will freeze in low temperatures 
of approximately -12°C (10°F). Disposable Lithium batteries 
have  a  much  lower  threshold  for  temperature  with  an 
estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors 
such as extremely cold temperatures. Extreme cold may 
temporarily reduce the effective range between the sensor 
and the base station. If the unit's performance fails due to 
low temperature, the unit will resume proper functioning 
as the temperature rises to within the normal temperature 
range (i.e. no permanent damage will occur to the unit due 
to low temperatures). 
Data  is  sent  from  the  sensor(s)  every  40  seconds.  The 
sensor  reception  icon  in  the  remote  sensor  area  shows 
the status.
To search for a sensor: 
Simultaneously, press and hold MEM and CHANNEL for 
2 seconds.
NOTE If the sensor is still not found, check the batteries, 
obstructions, and remote unit location.
CLOCK 
 CLOCK RECEPTION
This product is designed to synchronize its date and time 
automatically once it is within range of the WWVB-60 signal 
from the atomic clock in Boulder, Colorado.
 RECEPTION SIGNAL 
Clock signal reception indicator:
 SET CLOCK
To  manually  set  the  clock  make  sure  the  clock  signal 
reception is disabled. 
1. Press and hold MODE for 2 seconds.
2. Select the US time zone (Pacific (P), Eastern (E), Central 
(C) and Mountain (M)), hour, minute, year, month/day 
format,  month,  day  and  language.  Press    or    to 
change the setting.
3. Press MODE to confirm.
NOTE The language options are (E) English, (D) German, 
(F) French, (I) Italian, and (S) Spanish.
Press MODE to choose between the clock with seconds 
and clock with weekday display modes.
ALARM
To set the alarm:
1.  Press and hold ALARM for 2 seconds.
2.  Press   /   to set hour / minute. 
3.  Press ALARM or MODE to confirm.   indicates alarm 
is ON.
To toggle alarms ON / OFF:
1.  Press ALARM to display alarm time.
2.  Press ALARM again to turn alarm ON / OFF.
To silence the alarm:
•   Press SNOOZE to silence it for 8 minutes.
OR
•   Press any key except SNOOZE to turn the alarm off 
and activate it again after 24 hours. 
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather 
within a 30-50 km (19-31 mile) radius based on barometric 
pressure trend readings.
            ICON 
      DESCRIPTION
  
                        
       
Clear
Cloudy
Rainy
Partially Cloudy
��
��
��
��
��
��
��
��
��
��
��
��

The sensor collects temperature readings approx. every 
40 seconds and sends them to the main unit. The main 
unit can collect data from up to 3 sensors.
To set up the sensor:
1. Remove the screws from the battery door.
2. Insert the batteries, matching the polarity  (+ / -).
The sensor collects the radio signals whenever it is within 
1500 km (932 miles) of a signal.
NOTE Initial reception takes 2-10 minutes for first set up 
or when RESET is pressed. Once complete, the reception 
icon will stop blinking. If the signal is weak, it can take up 
to 24 hours to get a valid signal.
To enable and force a signal search:
 Press and hold   for 2 seconds.
To disable the signal reception:
Press and hold   for 2 seconds.
        flashes when it is disabled.
USER MANUAL
   ICON 
                         DESCRIPTION
  
                         
                         
                
 
                            
       
         and “- - . -“
         (Outdoor 
         temperature area)
The sensor cannot be found. 
Search for the sensor or check 
batteries
Sensor 1 is sending data 
A channel has been found
Main unit is searching 
for the sensor(s)
 STRONG SIGNAL    WEAK SIGNAL       NO SIGNAL
Wireless Weather Forecaster with 
Temperature Display and Self - Setting 
Atomic Clock
MODEL: BAR686A
BAR686_M
2005.12.12, 4:36 PM
1