Oregon Scientific RMR383HGA プリント

ページ / 2
NOTE  The language options are English (E), German (D), 
French (F), Italian (I), and Spanish (S).
To switch the clock display:
Press MODE to toggle between:
•      Clock with day 
•      Clock with seconds
 
ALARM
To set the alarm:
1.    Press and hold ALARM for 2 seconds.
2.    Press   /   to set alarm time.
3.    Press MODE/SNOOZE to confirm.   indicates alarm is 
ON.
To enable / disable the alarm:
1.    Press ALARM to display alarm time.
2.    Press ALARM again to turn alarm ON / OFF.
To silence the alarm:
•      Press SNOOZE to silence it for 8 minutes.
OR
•      Press any key except SNOOZE to turn the alarm off and 
activate it again after 24 hours. 
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Press °C / °F.
To view outdoor sensors temperature readings:
Press CHANNEL
To auto-scan between sensors:
Press and hold CHANNEL for 2 seconds. Each sensor’s data 
is displayed for 3 seconds.
To end auto-scan:
Press CHANNEL or MEM.
To  toggle  between  current,  minimum  and  maximum 
records for the selected sensor:
Press MEM repeatedly.
To clear the records:
Press and hold MEM for 2 seconds. 
TEMPERATURE AND HUMIDITY TREND
The  temperature  and  humidity  trend  icons  are  based  on 
recent readings.
         RISING                   STEADY                   FALLING
  
  
 
ICE WARNING 
If  the  channel  1  sensor  falls  between  3°C  to  –2°C  (37°F 
to  28°F),    flashes  to  warn  you  that  the  temperature  is 
approaching freezing. 
NOTE   The warning will automatically stop if the temperature 
goes outside the ice-warning range.
HI / LO TEMPERATURE / HUMIDITY ALARM
An  alarm  can  be  set  to  sound  if  sensor  set  to  channel  1 
records  above  or  below  a  temperature  /  humidity  of  your 
choice.  
To set alarm ON/OFF:
1.    Press and hold TEMP / HUMIDITY HI / LO  .  
2.    Use   and   to select high / low temperature / humidity 
alarm. Press TEMP / HUMIDITY HI / LO   to confirm.
3.    Press   /   to set alarm ON / OFF and press TEMP / 
HUMIDITY HI / LO   to confirm.
4.    If alarm has been activated, use   and   to select the 
temperature / humidity.
5.    Press TEMP / HUMIDITY HI / LO   to confirm.
To silence the alarm:
Press  any  key.  The  alarm  resets  automatically  and  will 
resound  if  the  hi  /  lo  temperature  selected  is  recorded 
again.
NOTE   The  THN132N  sensor  supplied  does  not  support 
humidity  readings.  To  enable  Hi  /  Lo  Humidity  alarm  a 
thermo-hygro sensor must be purchased and set to channel 
1. For further information on compatible sensors such as the  
THGR268 thermo-hygro sensor please check with your local 
retailer or go to www2.oregonscientific.com.
HEAT INDEX
The heat index combines temperature and humidity data to 
describe the actual temperature felt. The THN132N sensor 
supplied does not support heat index display. A thermo-hygro 
sensor must be purchased to enable heat index display for 
channels 1-3.
  WARNING              HEAT INDEX        MEANING
  Extreme danger     54.5°C (130°F)     Strong risk of  
                                 or above               dehydration / sun  
                                                              stroke
  Danger                   40.5 - 54°C           Heat exhaustion 
                                 (105 - 129°F)        likely
  Extremecaution      32.2 - 40°C           Possibility of heat  
                                 (90 - 104°F)          dehydration
  Caution                   26.6-31.7°C          Possibility of heat  
                                 (80- 89°F)             exhaustion
•      To display the heat index, press HEAT INDEX.
•      To  toggle  between  current  /  maximum  /  minimum 
readings, press HEAT INDEX, then press CHANNEL to 
select channel 1-3 or indoor, followed by MEM.
•      To toggle between temperature / humidity and heat index 
display,  press  and  hold  HEAT  INDEX  for  2  seconds. 
Press HEAT INDEX again to stop this feature.
NOTE   If the heat index is below 80°F / 26°C, if the selected 
sensor  does  not  support  humidity  measurement  or  if  the 
channel is not working, the heat index will display NA .
COMFORT ZONE
The  comfort  zone  assesses  the  climate  based  on  current 
temperature and humidity measurements.
  ICON          TEMPERATURE              HUMIDITY
                      Any                                   > 70%
                      20 - 25°C (68 - 77°F)       40 - 70%
                      Any                                   < 40%
MOON PHASE
•      When calendar is set press 
 or 
 to view the moon 
phase for the next / previous day.
•      Press and hold   or   to scan through the years (2001 
to 2099).
               New Moon
               Waxing Crescent
               First quarter
               Waxing Gibbous
               Full Moon
               Waning Gibbous
               Last quarter
               Waning Crescent
RESET
Press RESET to return to the default settings. 
PRECAUTIONS
This product is engineered to give you years of satisfactory 
service  if  you  handle  it  carefully.  Here  are  a  few 
precautions:
•      Do not subject the unit to excessive force, shock, dust, 
temperature or humidity, which may result in malfunction, 
shorter  electronic  life  span,  damaged  battery  and 
distorted parts.
•      Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.
•      Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 
•      Do  not  tamper  with  the  unit’s  internal  components. 
Doing  so  will  invalidate  the  warranty  on  the  unit  and 
may cause unnecessary damage. The unit contains no 
user-serviceable parts.
•      Only  use  fresh  batteries  as  specified  in  the  user’s 
instructions. Do not mix new and old batteries.
•      Due  to  printing  limitations,  the  displays  shown  in  this 
manual may differ from the actual display.
•      The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.
•      Do not dispose this product as unsorted municipal waste. 
Collection of such waste separately for special treatment 
is necessary.
NOTE  The technical specifications for this product and the 
contents of the user manual are subject to change without 
notice.
SPECIFICATIONS
  TYPE                              DESCRIPTION
  MAIN UNIT
  L x W x H                        110 x 69 x 140 mm    
                                          (4.3 x 2.7 x 5.5 in)
  Weight                             153 g (5.34 oz) without battery
  Temperature unit             °C / °F
  Temperature range         -5°C to 50°C (23°F to 122°F)
  Resolution                       0.1°C (0.2°F)
  Clock frequency              WWVB-60
  Synchronization              Auto or disabled
  Signal frequency             433 MHz
  Clock                               Auto or manual (disabled)
  Humidity range                25% - 95%
  Humidity resolution         1%
  MEM                               Min / Max relative humidity and 
                                          temperature
  Alarm duration                 2 minutes
  Snooze                            8 minutes
  Clock display                   HH:MM:SS 
 
                                          HH:MM:Day of Week
  Hour format                     12 / 24 hour format
  Calendar                         MM / DD or DD / MM language  
                                          selectable: E, D, F, I and S
  Power                              2 x UM-3 (AA) 1.5 V batteries
  REMOTE UNIT
  L x W x H                        96 x 50 x 22 mm  
 
                                          (3.8 x 2.0 x 0.9 in)
  Weight                             62 g (2.22 oz) without battery
  Transmission range        30 m (100 ft) unobstructed
  Temperature range         -30°C to 60°C (-22°F to 140°F)
  Power                              1 x UM-3 (AA) 1.5 V battery
NOTE   It  is  recommended  that  you  use  alkaline  batteries 
with this product for longer performance.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more 
about Oregon Scientific products such as digital cameras; 
MP3  players;  children’s  electronic  learning  products  and 
games; projection clocks; health and fitness gear; weather 
stations;  and  digital  and  conference  phones.  The  website 
also  includes  contact  information  for  our  Customer  Care 
department in case you need to reach us, as well as frequently 
asked questions and customer downloads.
We hope you will find all the information you need on our 
website, however if you’re in the US and would like to contact 
the  Oregon  Scientific  Customer  Care  department  directly, 
please visit:
www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
FCC STATEMENT
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
WARNING  Changes or modifications not expressly approved 
by the party responsible for compliance could void the user’s 
authority to operate the equipment.
NOTE   This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide 
reasonable  protection  against  harmful  interference  in  a 
residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency energy and, if not installed and used in accordance 
with  the  instructions,  may  cause  harmful  interference  to 
radio  communications.  However,  there  is  no  guarantee 
that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:
•      Reorient or relocate the receiving antenna.
•      Increase  the  separation  between  the  equipment  and 
receiver.
•      Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.
•      Consult the dealer or an experienced radio / TV technician 
for help.
DECLARATION OF CONFORMITY
The  following  information  is  not  to  be  used  as  contact  for 
support or sales. Please call our customer service number 
(listed on our website at www.oregonscientific.com), or on the 
warranty card for this product) for all inquiries instead.
We
Name:                Oregon Scientific, Inc.
Address:             19861 SW 95th Ave.,Tualatin,
                          Oregon 97062 USA
Telephone No.:   1-800-853-8883
declare that the product 
Product No.:       RMR383HGA
Product Name:   Wireless Indoor / Outdoor Thermometer  
                          with Indoor Humidity and Self-Setting  
                          Atomic Clock
Manufacturer:     IDT Technology Limited
Address:             Block C, 9/F, Kaiser Estate,
                          Phase 1,41 Man Yue St.,     
 
                          ung Hom, Kowloon, 
                          Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 1) This device may 
not cause harmful interference. 2) This device must accept 
any  interference  received,  including  interference  that  may 
cause undesired operation.
© 2006 Oregon Scientific. All rights reserved.