AquaPRO APB250UPRO ユーザーズマニュアル

ページ / 12
APB075PRO, APB100PRO, APB150PRO, APB200PRO, APB300PRO, 
APB100UPRO, APB150UPRO, APB200UPRO and APB250UPRO
or pump house must allow adequate 
ventilation to assure the ambient 
temperature remains below the motor 
rating when the pump is operating.
•  Locate pump on a non combustible 
surface. The surface should be hard, level, 
dry, well ventilated, out of direct sunlight. 
The surrounding area should provide 
protection from the elements and allow 
suffi cient space for maintenance and 
service. Ensure the drainage will fl ow 
away from the pump. To reduce vibration 
and pipe stress, use anchor bolts to 
secure pump base to surface. Support the 
suction and discharge piping.
•  Design the piping system to allow the 
pump suction inlet height to be as close 
to water level as possible. Mount pump 
below water level for easy priming. If the 
pump must be located above the fi lled 
water level, keep the vertical distance to 
a minimum. Use short, direct piping to 
the suction this will minimize friction loss. 
 
Fire and burn hazard. 
  Motors run at high 
temperatures. Do not allow leaves, debris, 
or foreign matter to collect around the 
pump motor. Keep ventilation holes open. 
Allow motor to cool before handling. Keep 
fl ammable liquids away.
•  If the thermal overload protection 
in the motor trips or if the GFCI trips 
determine the reason and correct the 
problem before re-starting pump.
•  Use rigid or fl exible PVC pipe. Ensure 
pipe ends are clean and free of any fl ash 
caused by cutting. Use the proper glue 
for the type of pipe selected. 
NOTE: Use a supplier recommended 
primer to ensure glued joints are secure.
Many local codes require primer with a 
purple tracer to verify primer use.
•  Consider climatic conditions when 
applying adhesives. Atmospheric 
conditions with high humidity will 
make the adhesive action of certain 
glues less effective. Follow the 
manufacturer’s instructions.
Pool Safety Guidelines 
RESPONSIBLE ADULT SUPERVISION
Constant and responsible adult supervi-
sion is mandatory in the pool or spa 
environment. Always supervise children 
around pools and spas. Never allow a child 
to play in a way that could permit the 
child’s hair to come near the drain cover.
DRAINS, SUCTION FITTINGS, AND JETS
Keep hair and clothing away from the suc-
tion fi tting drain cover. Wear a bathing cap 
or pin hair up if you have long hair. Current 
grates and covers help prevent body or hair 
entrapment. Make sure that drain covers 
meet the ANSI/ASME A112.19.8 standard. 
Safety doors should be installed in all pool 
cleaner wall suction lines. Pools or spas with 
drain covers that are broken, missing, or not 
adequately secured should not be used until 
the proper replacement has been installed.
ELECTRICAL HAZARDS
A licensed electrician, experienced in 
swimming pools and spas, should inspect 
your equipment to make sure everything is 
properly grounded, bonded, and pro-
tected by proper GFCI circuits according to 
Article 680 of the National Electric Code.
DROWNING PREVENTION
Install and routinely inspect fences, self-clos-
ing and latching gates, baby barrier fences, 
and alarms. Eliminate incidental routes to 
pool including machinery or equipment that 
provides a route over fencing into pool area.
INDOOR INSTALLATIONS
Pools and spas located indoors must 
comply with ANSI/ASHRAE (American 
Society of Heating, Refrigeration and 
Air-Conditioning Engineers) standard 
62-2001 to ensure adequate ventilation 
and safe use.
WARNING SIGNS
Protect your family and guests. Make 
sure that all warning signs provided by 
the manufacturer, builder, or installer 
are displayed according to the manufac-
turer’s specifi cations.
Installation
 
Shock Hazard! Only 
 qualifi ed, licensed 
personnel should install pump and wiring.
 A 
professional 
  trained and familiar 
with pool pump installation must perform 
pressure tests. 
General Safety 
Information 
(Cont.)
3
www.aquaprosystems.com
Figure 2
 Para Ordenar Repuestos o Asistencia Técnica,  Sírvase 
Llamar al Distribuidor Más Cercano a Su Domicilio 
 Dirija toda la correspondencia a:
AquaPRO
®
 Systems
Attn: Customer Service
101 Production Drive
Harrison, OH 45030  U.S.A.
 Sírvase darnos la siguiente información:
- Número del modelo
- Número de Serie o código con fecha (de haberlo)
- Descripción y número del repuesto según la lista
  de repuestos
22 Sp
Manual del usuario
1
19
15
14
9
6
17
7
16
10
5
3
2
18
20
21
12
8a
13
11
4
8b
22