Toshiba STE 58760 ユーザーズマニュアル

ページ / 116
 
STE 58760 
-    -
 
iii 
 
 
NOTE! 
FOR EUPOREAN UNION (EU)
 
In European Union (EU), there are following limitations and notes to approve the 
CE Marking EMC Direction.    In other countries and areas, it 
is not necessary to 
apply to these limitations and notes.
 
 
(1)  Set up conditions 
 
 
The following type of power line transformer must be used. 
 
Frequency: 
50 or 60 Hz 
 
Secondary voltage: 
3 phase 200 ~ 230 VAC 
 
power capacity: 
Min. 2.7 kVA 
 
(2) Input power condition 
 
 
Core wires: 
3.5 mm
2
 ~ 5.5 mm
2
 
 
Voltage short interruption:  0.5 cycle 
 
(3) Ground 
 
 
 Core 
wires: 
0.08 
mm
2
 ~ 0.5 mm
 
 
 
Ground condition: 
Exclusive ground line for robot ground impedance 
must be less than 100 
Ω
.
 
 
(4)  External input and output line / Optional input and output line 
 
 
 
Core wires: 
0.08 mm
2
 ~ 0.5 mm
 
 
Shield: Ground 
shield 
 
 
Cable length: 
Max. 10 m 
 
 
Manufacturing method: 
Refer to figure A. 
   
  S
ignal ground: 
Voltage potential between signal ground PGBA and 
controller frame ground F.G. must be the same. 
 
(5) Serial communication line 
 
 
    Only 1 of 4 serial communication ports (connector name; J1 ~ J4) can be used at 
the same time.
 
 
 
Core wires: 
0.08 mm
2
 ~ 0.5 mm
2
 
 
 
Shield: Ground 
shield
 
 
 
Cable length: 
Max. 10 m
 
 
 
Twisted pair: 
Not required for RS-232C, required for RS-422.
 
 
 
Manufacturing method: 
Refer to figure A.