Beckett 0602-20 ユーザーズマニュアル

ページ / 21
7
6
Inserting  Battery  Pack  onto  Tool
(Fig. 1 & 2)
Battery pack can be inserted onto the tool
in  two  ways.
1. For  working  in  restricted  spaces.
Insert the battery pack from the front
by sliding battery pack onto the body
of the tool. Insert the battery pack until
the battery latches lock.
Fig. 1
Remove the battery pack from the tool
for  charging  when  the  tool  can  no
longer  perform  its  intended  function
(i.e., drilling, cutting, etc.).
Leave  the  battery  pack  on  the
charger after it has reached a full
charge; the pack will continue to re-
ceive  a  trickle  charge  to  ensure  capacity
is maintained.
Occasionally  (once  a  week)  leave  the
batteries  on  the  charger  overnight  to
help  maintain  cell  balance.
Do  not  store  the  battery  on  the
charger  (for  more  than  24  hours);  this
could  reduce  battery  life.
Never  leave  batteries  on  chargers
where  power  interruptions  are  com-
mon.  Damage  to  the  battery  cells  could
occur.
Store  batteries  at  room  tem-
perature  away  from  moisture.
Do  not  store  in  damp  locations
where  corrosion  of  terminals  may  occur.
Do not submerge your battery or cord-
less tools in water. This will damage the
battery and tool.
Charge  unused  batteries  overnight
at  least  every  six  months  to  maximize
battery  life.  Unused  batteries  discharge
at a rate of about 1% per day and will be
fully discharged after six months.  For bat-
teries  stored  for  a  long  time,  two  to  ten
normal  charging  cycles  may  be  required
before the pack is fully charged.
Do  not  use  oil  or  solvents  to  clean  or
lubricate your  battery pack.  The  plastic
casing will become brittle and crack, caus-
ing a risk of injury.
2. For  optimum  weight  distribution  and
balance.
Insert the battery pack from the back
by  sliding  the  battery  pack  onto  the
body of the tool. Insert the battery pack
until the battery latches lock.
3. To remove the battery pack, press in
both battery latches and slide the bat-
tery pack off of the tool.
Fig. 2
WARNING!
Charge only MILWAUKEE 12, 14.4
and  18  Volt  battery  packs  in
MILWAUKEE  chargers.  Other
brands  of  batteries  may  explode
causing  personal  injury  and
damage.
For  specific  charging  instruc-
tions,  please  read  the  operator's
manual  supplied  with  your
charger.
Capacities
Steel
3/8"
1/2"
High  Speed
Flat Bit in
Wood
7/8"
1"
Auger  Bit
in  Wood
1"
1-1/8"
Hole  Saw
in  Wood
1-1/4"
1-3/4"
Screws  (dia.)
in Wood
1/4"
1/4"
Pathfinder
Bit
7/8"
1-1/4"
Cat. No.
0602-20
0612-20
Direct Current
Properly  Recycle
Nickel Cadmium
Batteries
Symbology
Underwriters
Laboratories,  Inc.
No Load Revolutions
per Minute (RPM)
Low  Speed
Steel
3/8"
1/2"
Specifications
Cat. No.
0602-20
0612-20
Volts  DC
12
14.4
No Load RPM
Low 0 - 400
High 0 - 1400
Low 0 - 400
High 0 - 1400
BATTERY PACK CARE AND USE
EXTENDING  AND  MAINTAINING
 BATTERY PACK LIFE
Charge  the  new  battery  pack
overnight  before  use  to  allow
the  cells  to  become  fully
charged. New battery packs are not fully
charged.  Two  to  ten  normal  charging/
discharging  cycles  may  be  required  be-
fore the pack can take its maximum charge.
Never  completely  discharge
the  battery  pack.  MILWAUKEE
battery  packs  do  not  develop  a
"memory" when charged after only a par-
tial  discharge.  Taping-on  triggers  or  leav-
ing  work  lights  on  for  extended  periods
to  completely  discharge  the  battery  pack
will reduce its life by upsetting the electro-
chemical balance and can result in short-
circuiting  of  the  battery.
Do  not  charge  batteries  in  hot
or  cold  places  (below  40°F  (5°C)
or above 105°F (40°C)). Temperature
extremes reduce the ability for battery pack
cells to hold a charge. Do not store batter-
ies  where  the  temperature  may  exceed
120°F (50°C), such as in a vehicle or metal
building during the summer.
To avoid overheating to a battery pack,
allow  cordless  tools  cool  down  be-
tween  high  torque  drilling/cutting
applications.  The  increased  energy  dis-
charge rate will heat the battery pack cells
faster than the cells can release the heat.
This could damage the cells.
After  use,  allow  a  hot  battery  pack  to
cool to room temperature before inserting
it into the charger. If a hot battery is put on
a charger, charging will not begin until the
battery has cooled to a safe temperature.
See  your  charger  manual  for  more  infor-
mation on charging temperatures. Charg-
ing a hot battery will damage the cells.
Never  forcibly  heat  up  or  cool  down
batteries.  This  will  damage  some  cells  in
the pack, causing them to not be able to hold
a charge.
MILWAUKEE battery packs will operate for many years and/or hundreds of cycles when
they  are  used,  charged,  and  stored  according  to  these  instructions.  Properly  using,
charging, and storing your battery pack can greatly extend its life.