Model h6331 hVhp spray gun set
-16
-
troubleshooting
symptom
possible cause
solution
Fluttering or spitting 
spray.
1. dry or worn fluid tip seat per-
mits air to seep into fluid pas-
sage.
2. Material level too low.
3. Fluid tip or filter obstructed.
4. dry needle packing.
1. tighten fluid tip or replace 
seat with new one.
2. add material.
3. Clean
4. lubricate needle.
uneven top or bot-
tom pattern. 
1. atomizing cap holes are 
obstructed.
2. Build-up material on top or 
bottom of fluid tip.
3. Build-up material on atomizing 
cap is on needle seat.
1. Clear holes.
2. Clean.
3. Clean.
right or left arc 
pattern.
1. left or right side horn holes 
are plugged.
2. Build-up on left or right side of 
fluid tip.
3. Build-up of material inside 
atomizing cap.
1. Clear holes.
2. Clean.
3. Clean.
heavy deposit of 
material in center.
1. the material flow exceeds the 
atomizing cap capacity.
2. inlet air pressure is too low.
3. Material is too thick.
1. reduce fluid flow.
2. increase inlet air pressure.
3. thin material.
narrow center pat-
tern.
1. Volume control turned in too 
far.
2. inlet air pressure too high.
3. Fluid pressure is too low.
4. Material is too thin.
1. increase volume.
2. reduce inlet air pressure.
3. increase fluid pressure.
4. adjust material.
no spray output.
1. no pressure at gun.
2. Fluid passages dirty.
3. Fluid control closed.
4. out of paint.
5. Material too thick.
1. Check air supply.
2. Clean gun, remove any 
obstructions.
3. open.
4. refill.
5. thin to manufacturer's rec-
ommendations.