Freedom SW 230V Installation Guide
Stacking Features
Parallel Stacking
Allows the inverter and charger capacity of a system to be doubled.
Parallel-stacked inverter/chargers can operate from different battery
banks, meaning each unit is connected to its own battery bank.
However, it is highly recommended to only use a single battery
bank. See “DC Connections for Stacked Inverters” on page 43.
Parallel-stacked inverter/chargers can operate from different battery
banks, meaning each unit is connected to its own battery bank.
However, it is highly recommended to only use a single battery
bank. See “DC Connections for Stacked Inverters” on page 43.
Do NOT connect a stacking cable to the STACKING port on the
front panel of a Freedom SW 230V to configure two units for
parallel stacking. The port is reserved for future use.
front panel of a Freedom SW 230V to configure two units for
parallel stacking. The port is reserved for future use.
CLEAR FAULT
RESET
INVERTER
ENABLED
ENABLED
Inverter
On
AC/
Charge
Fault
FREEDOM
SW
INVERTER/CHARGER
STACKING
XANBUS INTERFACE
CLEAR FAULT
RESET
INVERTER
ENABLED
ENABLED
Inverter
On
AC/
Charge
Fault
FREEDOM
SW
INVERTER/CHARGER
STACKING
XANBUS INTERFACE
Two Freedom SW 3524-230 units shown.
Figure 16 Parallel Stacking Using Two Freedom SW 3524-230s
L
NEUTRAL
GROUND
NEUTRAL
GROUND
30A
30A
Two Freedom SW 3524-230 units shown.
Freedom SW 3K2K 230V InvChg Install Guide.book Page 42 Friday, June 20, 2014 9:11 AM