G8027 1 HP Dust Collector
Ensure  that  the  entire  system  is  grounded.  If 
using  plastic  blast  gates  to  direct  air  flow,  the 
grounding  wire  must  be  jumped  (
Figure  15
around  the  blast  gate  without  interruption  to  the 
grounding system.
Figure 15. Ground jumper wire when using 
plastic blast gates or elbows and metal duct.
Plastic Blast Gate
Metal Duct
Copper Ground Wire
Figure 16. Flex-hose grounded to machine.
Ground Screw
Flex-Hose
Internal Ground Wire
External Ground Wire
We also recommend wrapping the outside of all 
plastic ducts with bare copper wire to ground the 
outside  of  the  system  against  static  electrical 
build up. Wire connections at Y’s and T’s should 
be made with wire nuts.
Attach  the  bare  ground  wire  to  each  stationary 
woodworking  machine  and  attach  the  dust  col-
lector  frame  with  a  ground  screw  as  shown  in 
Figure 16. Ensure that each machine is continu-
ously grounded to the grounding terminal in your 
electric service panel.