Chicago Pneumatic CPVS 40 ユーザーズマニュアル

ページ / 24
Chicago Pneumatic Compressors
62 305 258 65
01/2008
Page 3
 CPVS Model
40
50
60
75
Motor power
(hp)
40
50
60
75
Main Voltage 460 Volt / 3 / 60 Hz
Nominal current
(A)
69
81
89
125
Power supply cable
AWG 4
AWG 3
AWG 1
AWG 0
Fuse protection
(Type RK5)
80
100
125
150
Connection of the electric plate to an external control box
• Install an RC filter on the KM1 coil.
• Install an RC filter on the KM2 coil.
• All connections between external parts and the compressor must be carried out using a shielded cable, which must be grounded at one of its
ends.
WARNING: the operation connection cables between the different elements must never follow the same path as the existing power
cords. A separate installation from the power cords must be carried out.
• Install an RC filter on all the relay coils of the external operation units.