Grizzly G0656X ユーザーズマニュアル

ページ / 66
G0656 8" Jointer with Built-In Mobile Base
-33-
Symptom
Possible Cause
Possible Solution
Tables  are  hard  to 
adjust.
1.  Table lock is engaged or partially engaged.
2.  Infeed table stops blocking movement.
1.  Completely loosen the table lock.
2.  Loosen/reset infeed table positive stops.
Table
Symptom
Possible Cause
Possible Solution
Excessive 
snipe 
(gouge  in  the  end 
of  the  board  that  is 
uneven with the rest 
of the cut).
1.  Outfeed table is set too low.
2.  Operator  pushing  down  on  trailing  end  of 
the workpiece.
1.  Align outfeed table with cutterhead knife at top dead 
center (
Page 17).
2.  Reduce/eliminate downward pressure on that end of 
workpiece.
Workpiece  stops  in 
the  middle  of  the 
cut.
1.  Outfeed table is set too high.
1.  Align outfeed table with cutterhead knife at top dead 
center (
Page 17).
Chipping.
1.  Knots or conflicting grain direction in wood.
2.  Nicked or chipped blades.
3.  Feeding workpiece too fast.
4.  Taking too deep of a cut.
1.  Inspect  workpiece  for  knots  and  grain  (
Page  21); 
only use clean stock.
2.  Adjust  one  of  the  nicked  knives  sideways;  replace 
knives (
Page 34).
3.  Slow down the feed rate.
4.  Take a smaller depth of cut. (Always reduce cutting 
depth  when  surface  planing  or  working  with  hard 
woods.)
Fuzzy Grain.
1.  Wood  may  have  high  moisture  content  or 
surface wetness.
2.  Dull knives.
1.  Check  to  make  sure  moisture  content  is  less  than 
20% and allow to dry if moisture is too high.
2.  Sharpen or replace knives (
Page 34).
Long  lines  or  ridges 
that  run  along  the 
length of the board
1.  Nicked or chipped knives.
1.  Adjust  one  of  the  nicked  knives  sideways;  replace 
knives (
Page 34).
Uneven 
cutter 
marks,  wavy  sur-
face,  or  chatter 
marks  across  the 
face of the board.
1.  Feeding workpiece too fast.
2.  Knives not adjusted at even heights in the 
cutterhead.
1.  Slow down the feed rate.
2.  Adjust  the  knives  so  they  are  set  up  evenly  in  the 
cutterhead (
Page 34).
Board  edge  is  con-
cave or convex after 
jointing.
1.  Board  not  held  with  even  pressure  on 
infeed and outfeed table during cut.
2.  Board started too uneven.
1.  Hold board with even pressure as it moves over the 
cutterhead.
2.  Take partial cuts to remove the extreme high spots 
before doing a full pass.
Cutting
Motor & Electrical Continued
Symptom
Possible Cause
Possible Solution
Machine  has  vibra-
tion  or  noisy  opera-
tion.
5.  Motor mount loose/broken.
6.  Machine  is  incorrectly  mounted  or  sits 
unevenly.
7.  Motor fan is rubbing on fan cover.
8.  Motor bearings are at fault.
9.  Cutterhead bearings at fault.
10. Centrifugal switch loose.
5.  Tighten/replace.
6.  Relocate machine.
7.  Replace  dented  fan  cover;  replace  loose/damaged 
fan.
8.  Test by rotating shaft; rotational grinding/loose shaft 
requires motor replacement.
9.  Replace bearing(s)/realign cutterhead.
10. Replace.