Jet Tools J-4401A ユーザーズマニュアル

ページ / 32
 
17
10.0  Troubleshooting 
Symptom Possible 
Cause 
Correction 
Motor will not run 
Voltage is too low. 
Check power supply for proper voltage. 
Branch circuit fuse is blown or circuit 
breaker is tripped. 
Determine the reason for the blown fuse or 
tripped circuit breaker; then replace the fuse 
or reset the breaker. 
Branch is shut down for service. 
Check all personnel and machines on  
    
the branch to be certain someone has  
    
not shut down the branch for service. DO 
NOT replace the fuse or reset the breaker 
unless you are certain no personnel are 
working on the machines, wires or controls in 
the circuit. 
Open circuit in the wiring. 
Inspect all wire connections for loose or 
open connections. 
Motor is defective. 
Replace the motor. 
Switch is defective. 
Replace the switch. 
Motor 
stalls 
easily 
Low 
voltage. 
Check for proper voltage at the motor; 
correct as necessary. 
Fuse blown (three phase motors only). 
Replace the blown fuse. 
Improper wiring. 
Check for proper connections. 
Abrasive belt or disc 
slows down although 
motor keeps running at 
working speed 
Belt is slipping. 
Replace the belt. 
Poor tracking 
Tracking is out of adjustment. 
Adjust the belt tracking. 
Too much belt tension. 
Loosen the tension until the belt is just taut. 
Not enough belt tension. 
Tighten the tension until the belt is more taut. 
Belt is jointed improperly. 
Check belt for an irregular seam or shape. 
Lack of crown on the drive roller. 
Remove the belt and put a straight edge 
along the drive roller. There should be a 
slight crown (high spot toward the middle of 
the roller.) If the crown has worn away, 
replace the roller. 
Worn bearings. 
Check all the bearings for excessive heat or 
loose shafts. Replace if necessary. 
Unsteady belt 
Slack in the abrasive belt 
Adjust the belt tension. 
Short 
belt 
life 
Excessive pressure applied while 
grinding. 
Allow the belt to do the cutting. Excessive 
pressure only dulls the grit and removes it 
from the cloth. 
Working on only one side of the belt or 
only in one area of the disc. 
Use all surface areas of the abrasive cloth. 
Incorrect 
abrasive 
material 
or 
grit 
size. 
Check with your abrasives supplier for 
recommendations on the type and 
coarseness of the abrasive required for the 
workpieces you are sanding or grinding. 
 
CAUTION: For all of the electrical faults and corrections in the above table JET recommends the use of a qualified 
and licensed electrician for all circuit tracing, diagnosis and repair.