Jet Tools J-4202A ユーザーズマニュアル

ページ / 32
 
15
 
Figure 20: Location of adjustment (socket head) 
screws and pointer attachment screw for table angle 
adjustment. 
 
Figure 21:  Locations of stop lugs and stop bracket for 
zero and 45° table positions. 
8.7  Adjusting or replacing the platen 
1.  Disconnect the electrical power to the machine to 
prevent accidental start-ups. 
2.  Remove the top cover, side guard and belt as 
outlined in section 7.1, Belt replacement
3.  Remove the table by unscrewing the locking 
handling and lifting the complete table assembly, 
from the machine. 
4.  If you are replacing the platen, remove the three 
screws that hold it to its mount -- then install the 
new platen and replace the mounting screws 
finger tight. 
5.  If you are only adjusting the platen, loosen the 
three mounting screws to allow adjustment. 
6.  Using a straight edge as shown in Figure 22, 
adjust the platen height until it is 1/32 inch higher 
than the crown of both the drive and idler drums. 
7.  Tighten the platen adjustment screws. 
8.  Reinstall the table and belt. 
9.  Check and adjust, if necessary, the tracking of 
the belt according to instructions in section 7.1, 
Belt replacement
10.  Reinstall the guards and covers. 
11.  Check and adjust the table angles and miter slot 
squareness according to table adjustment 
instructions in this manual. 
12.  Reconnect the electrical power to the machine. 
 
Figure 22:  Method for adjusting height of platen 
above drive and idler drums. 
 
9.0  Electrical connections 
Caution:  JET sanders are available in a wide variety 
of electrical configurations to meet the needs of the 
purchaser with respect to power available and 
compliance with electrical codes.  Each machine is 
tested at the factory for operation before shipment 
and the power cord is tagged with the power 
requirements for the machine, as shipped. 
HOWEVER, before attempting any electrical hookup, 
you should be certain:
 
1.  The electrical characteristics of the service 
branch match the requirements of the motor.   
2.  The service branch is equipped with wires of the 
required gauge or size. 
3.  The branch circuit intended for the machine is 
protected with a time delay fuse or circuit breaker 
with rated amperage just slightly greater than the 
full load current of the motor. 
 
MOTOR AMPERAGE full load current 
 
Phase Voltage Amperage 
1 115 
20 
1 220 
10 
   
3 220 
5.2 
3 440 
2.6