Tektronix TDS460A ユーザーズマニュアル
![Tektronix](https://files.manualsbrain.com/attachments/8290919ac2d59d4854d7f6390d5fb3959ff4166e/common/fit/150/50/57e6c08abf656d2a0ea515316e8dc2a0925b9a4e11d84eeaf6a6a2925654/brand_logo.png)
Command Descriptions
2–208
TDS Family Oscilloscope Programmer Manual
OFF turns off waveform averaging.
AVErage turns on waveform averaging.
MATH1:PROCESSING OFF
ensures that waveform averaging is not in use on math waveform 1.
ensures that waveform averaging is not in use on math waveform 1.
MATH1:PROCESSING AVERAGE
turns on waveform averaging on math waveform 1.
turns on waveform averaging on math waveform 1.
MEASUrement? (Query Only)
Returns all measurement parameters.
Measurement
MEASUrement?
MEASUrement
?
MEASUREMENT?
might return
:MEASUREMENT:MEAS1:TYPE PERIOD;UNITS "s";SOURCE1 CH1;SOURCE2
might return
:MEASUREMENT:MEAS1:TYPE PERIOD;UNITS "s";SOURCE1 CH1;SOURCE2
CH1;DELAY:EDGE1 RISE;EDGE2 RISE;DIRECTION FORWARDS;:MEASUREĆ
MENT:MEAS1:STATE 0;:MEASUREMENT:MEAS2:TYPE PERIOD;UNITS
"s";SOURCE1 CH1;SOURCE2 CH1;DELAY:EDGE1 RISE;EDGE2 RISE;DIRECTION
FORWARDS;:MEASUREMENT:MEAS2:STATE 0;:MEASUREMENT:MEAS3:TYPE
PERIOD;UNITS "s";SOURCE1 CH1;SOURCE2 CH1;DELAY:EDGE1 RISE;EDGE2
RISE;DIRECTION FORWARDS;:MEASUREMENT:MEAS3:STATE 0;:MEASUREĆ
MENT:MEAS4:TYPE PERIOD;UNITS "s";SOURCE1 CH1;SOURCE2
CH1;DELAY:EDGE1 RISE;EDGE2 RISE;DIRECTION FORWARDS;:MEASUREĆ
MENT:MEAS4:STATE 0;:MEASUREMENT:IMMED:TYPE PERIOD;UNITS
"s";SOURCE1 CH1;SOURCE2 CH1;DELAY:EDGE1 RISE;EDGE2 RISE;DIRECTION
FORWARDS;:MEASUREMENT:GATING 0;METHOD HISTOGRAM;REFLEVEL:METHOD
PERCENT;ABSOLUTE:HIGH 0.0E+0;LOW 0.0E+0;MID 0.0E+0;MID2
0.0E+0;:MEASUREMENT:REFLEVEL:PERCENT:HIGH 90.0E+0;LOW 10.0E+0;MID
50.0E+0;MID2 50.0E+0
MEASUrement:CLEARSNapshot
Removes the measurement snapshot display.
Arguments
Examples
Group
Syntax
Example