Mitsubishi Electronics MDS-D-SPJ3 ユーザーズマニュアル

ページ / 284
MDS-D/DH Series Specifications Manual
Appendix 6-2 Notes for AC servo/spindle system
Appendix 6 - 3
Appendix 6-2-4 Peripheral devices
To comply with UL/c-UL Standard, use the peripheral devices which conform to the corresponding standard.
Circuit Protector, Fuses, Magnetic contactor and AC Reactor
Circuit Protector for spindle motor Fan
Select the Circuit Protector by doubling the spindle motor fan rated.
A rush current that is approximately double the rated current will flow, when the fan is started
<Notice>
Applicable power 
supply unit
UL489 Circuit 
Protector
UL Fuse
Class K5
Magnetic 
contactor (AC3)
AC Reactor
MDS-D-CV-37
20A
30A
S-N12
D-AL-7.5K
MDS-D-CV-75
40A
60A
S-N25
D-AL-7.5K
MDS-D-CV-110
60A
70A
S-N35
D-AL-11K
MDS-D-CV-185
100A
125A
S-N65
D-AL-18.5K
MDS-D-CV-300
150A
200A
S-N95
D-AL-30K
MDS-D-CV-370
200A
225A
S-N150
D-AL-37K
MDS-D-CV-450
225A
250A
S-N300
D-AL-45K
MDS-D-CV-550
300A
400A
S-N300
D-AL-55K
MDS-DH-CV-37
10A
10A
S-N12
DH-AL-7.5K
MDS-D-HCV-75
20A
25A
S-N12
DH-AL-7.5K
MDS-DH-CV-110
30A
35A
S-N21
DH-AL-11K
MDS-DH-CV-185
50A
70A
S-N25
DH-AL-18.5K
MDS-DH-CV-300
75A
110A
S-N50
DH-AL-30K
MDS-DH-CV-370
100A
125A
S-N65
DH-AL-37K
MDS-DH-CV-450
125A
150A
S-N80
DH-AL-45K
MDS-DH-CV-550
150A
200A
S-N95
DH-AL-55K
MDS-DH-CV-750
200A
300A
S-N150
DH-AL-75K
Applicable 
drive unit
UL 489 Circuit 
Protector (240Vac)
UL Fuse
Class T (300Vac)
Magnetic 
contactor (AC3)
MDS-D-SVJ3(#)-03(##)
5A
10A
S-N12
MDS-D-SVJ3(#)-04(##)
5A
20A
S-N12
MDS-D-SVJ3(#)-07(##)
5A
20A
S-N12
MDS-D-SVJ3(#)-10(##)
10A
20A
S-N12
MDS-D-SVJ3(#)-20(##)
15A
40A
S-N21
MDS-D-SVJ3(#)-35(##)
20A
70A
S-N21
MDS-D-SPJ3(#)-075(##)
5A
15A
S-N12
MDS-D-SPJ3(#)-22(##)
15A
40A
S-N12
MDS-D-SPJ3(#)-37(##)
30A
60A
S-N21
MDS-D-SPJ3(#)-55(##)
40A
90A
S-N25
MDS-D-SPJ3(#)-75(##)
50A
125A
S-N25
MDS-D-SPJ3(#)-110(##)
75A
175A
S-N50
- For installation in United States, branch circuit protection must be provided, in accordance with the National Electrical 
Code and any applicable local codes.
- For installation in Canada, branch circuit protection must be provided, in accordance with the Canadian Electrical Code 
and any applicable provincial codes.