Mitsubishi Electronics MDS-R ユーザーズマニュアル

ページ / 362
 
5. Peripheral Devices 
 
 
 
 
 
5 - 3
 
(3)  600V bridge polyethylene insulated wire (IC) 105
o
C product 
(Example according to JEAC8001) 
Power input 
CN30 
(L1, L2, L3,     ) 
Regenerative option
CN30 
(P, C) 
Motor output 
CN31L、CN31M 
(LU,LV,LW,    ) 
(MU,MV,MW,    ) 
Control power 
(24VDC) 
CN22 
Magnetic brake 
CN9 
Terminal 
name 
 
 
Unit type 
mm
2
 AWG mm
2
 AWG mm
2
 AWG mm
2
 AWG 
MDS-R-V1-20 2  14 
2  14 
MDS-R-V1-40 2  14 
2  14 
MDS-R-V1-60 2  14 
2  14 
Servo drive unit 
 
MDS-R-V1-80 2  14 
2 14 
2 14 
1.25 to 2
14 to 16
MDS-R-V2-2020 2 
14 
14 
MDS-R-V2-4020 2 
14 
14 
MDS-R-V2-4040 2 
14 
14 
MDS-R-V2-6040 2 
14 
14 
MDS-R-V2-6060 2 
14 
14 
MDS-R-V2-8040 2 
14 
14 
MDS-R-V2-8060 3.5 
12 
14 
Servo drive unit  
(2-axis) 
MDS-R-V2-8080 3.5 
12 
2 14 
2 14 
1.25 to 2
14 to 16
 
 
 
 
 
 
CAUTION
 
1.  Selection conditions follow IEC/EN60204-1, UL508C, JEAC8001. 
 Ambient temperature is maximum 40°C. 
 Cable installed on walls without ducts or conduits. 
To use the wire under conditions other than above, check the standards you 
are supposed to follow. 
2.  The maximum wiring length to the motor is 30m. 
If the wiring distance between the drive unit and motor is 20m or longer, use a 
thick wire so that the cable voltage drop is 2% or less. 
3.  Twist the wire for the regenerative option connection wire. 
4.  Always wire the grounding wire.