Appendix 2. Selection 
 
 
 
 
 
A2 - 8
Appendix 2-2-2  Calculating the positioning frequency 
 
Select the regenerative resistor so that the positioning frequency DP (times/minute) calculated from the 
regenerative resistor capacity P
R
 (W) and regenerative energy E
R
 (J) consumed by the regenerative 
resistor is within the range shown in expression (2-10). For the unbalance axis, calculate using the 
regenerative energy E
R
 per reciprocation operation, and judge the number of operation cycles for rising 
and lowering as DP. 
 
P
R
DP < 48 
 
E
R
(times/minute)
   (
2-10)
 
Table 2-5  List of regenerative option correspondence 
Regenerative 
resistor type 
(Japan 
Resistor) 
GZG80 
W26 
OHMJ 
GZG200 
W26 
OHMJ 
GZG300
W20 
OHMJ 
GZG400
W13 
OHMJ
GZG400
W8 
OHMJ
GZG200
W120 
OHMJ 
3 units 
connected 
in parallel
GZG200
W39 
OHMJ 
3 units 
connected 
in parallel
GZG300
W39 
OHMJ 
3 units 
connected 
in parallel
GZG200 
W20 
OHMJ 
3 units 
connected 
in parallel 
GZG300
W20 
OHMJ 
3 units 
connected 
in parallel
GRZG400
-2 
OHMJ 
4 units 
connected 
in serial
Regenerative 
resistor unit 
type 
 
 
 
 
 
MR-RB32 MR-RB30 MR-RB50 MR-RB31 MR-RB51 MR-RB65
Regenerative 
capacity 
40W 100W 150W 200W
200W
300W  300W 500W 300W 500W 800W 
Resistance 
value 
26Ω 
26
 20 13
8
 40 13 13 6.7 6.7 
8
 
MDS-R-V1-20 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V1-40 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V1-60 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V1-80 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-2020 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-4040 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-6040 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-6060 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-8040 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-8060 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-8080 
 
 
 
 
 
 
 
 
 
 
 
 (Note) Types indicated with a 
∆ cannot be used when driving the HF353 motor.