Mitsubishi Electronics MDS-R ユーザーズマニュアル

ページ / 362
 
Appendix 4. EMC Installation Guidelines 
 
 
 
 
 
A4 - 12
 
MX13 Series 3-phase high attenuation noise filter for 200V 
 
 Features 
 
Perfect for mounting inside control panel: 
 Easy mounting and maintenance work:  
  Terminals are centrally located on the 
front 
 Complaint with NC servo and AC servo 
noise: 
  High attenuation of 40dB at 150KHz 
 Safety Standards: 
  UL1283, CSA22.2 No.8, EN133200 
 Patent and design registration pending 
 
 
 Specifications 
Type 
Item 
MX13030 MX13050 MX13100 MX13150 
1  Rated voltage (AC) 
3-phase 250VAC (50/60Hz) 
2  Rated current (AC)                           
30A 50A 100A 
150A 
Test voltage (AC for one minute across 
terminal and case) 
2500VAC (100mA) at 25°C, 70% RH 
Insulation resistance (500VDC across 
terminal and case) 
100M
 min. at 25°C, 70% RH 
5  Leakage current (250V, 60Hz) 
3.5 mA max. 
8 mA max. 
6 DC 
resistance 
30 m
 max. 
11 m
 max. 
5.5 m
 max. 
3.5 m
 max. 
7 Temperature 
rise 
30°C max 
8  Working ambient temperature 
–25°C to +85°C 
9  Working ambient humidity 
30% to 95% RH (non condensing) 
10  Storage ambient temperature 
–40°C to +85°C 
11  Storage ambient humidity 
10% to 95% RH (non condensing) 
12 Mass (typ) 
2.8kg 3.9kg 11.5kg 16kg 
(Note)  This is the value at Ta
50°C. 
 
Refer to the following output derating for Ta>50°C. 
 
Contact: Densei-lambda Co., Ltd.  Telephone: 03-3447-4411 (+81-3-3447-4411) 
 