Lincoln Electric IM528-B ユーザーズマニュアル

ページ / 54
OPERATION
22
WARNING
ELECTRODE
WORK
V
1
2
3
4
4
5
6
7
REAR CONNECTIONS
FIGURE 8
1   WARNING INFORMATION - Important information
regarding the safe installation, operation, and
servicing of the TIG Module.
2   INPUT  RECEPTACLE - For connecting the
Control Cable from the power source.  This
receptacle contains the following circuits:  Input
power, power source contactor control (where
applicable) and power source remote control
(where applicable).  This is a 9-pin receptacle.
3  WATER VALVE FITTINGS (OPTIONAL) - Water
valve inlet and outlet fittings, 5/8-18 left-hand
threads.  For connection of cooling water to and
from the TIG torch. Supplied as part of the optional
K844-1 Water Valve Kit.
4  POWER INPUT CONNECTIONS - Connections for
the work (bottom) and electrode (top) cables from
the Ranger power source.  1/2-13 threaded stud
connections.
5  POWER OUTPUT CONNECTIONS - Connections
for the work lead (bottom) and TIG torch (top).  1/2-
13 threaded stud connections.
6  GAS VALVE FITTINGS - Gas valve inlet and outlet
fittings, 5/8-18 right hand threads.  For connection
of the shielding gas supply and the TIG torch gas
fitting.
7  ARC START SWITCH / AMPTROL RECEPTACLE -
6-socket receptacle for connecting an arc start
switch or an Amptrol remote current control.
TIG MODULE