Mitsubishi Electronics 60/60S ユーザーズマニュアル

ページ / 559
3.  Tool Offset (M system) 
3.2  Tool Registration 
 
 
 
I-123 
Refer to "3 (I). Tool Offset (L system)" for L system.
3.2.5  Manual numeric Command Operation on the TOOL REGISTRATION Screen (M, T) 
 
 
To execute a manual numeric command on the TOOL REGISTRATION screen, first change the mode from 
usual data setting to manual numeric command. The M and T commands can be executed by screen 
operation in manual numeric command mode. 
 
 
(1)  Changing the mode from usual data setting to manual numeric command 
 
 
In the usual data setting mode, the cursor is 
displayed in the data setting field. It is not 
displayed in manual numeric command mode. By 
checking this difference, make sure that the mode 
has changed. Change the mode by the following 
operations:
 
 
T                      M 
MG(     )TOOL(     )D(  )AUX( ) 
 
 
Set 
 
 
  (Manual) in the first 
parenthesis pair of the setting field. 
T                      M 
MG(    M )TOOL(     )D(  )AUX( ) 
 
 
 
1)  This operation is necessary regardless of the 
command (M, T). 
 
Press the 
 
 
INPUT 
  key. The mode 
changes to manual numerical 
command. 
T                      M 
MG(     )TOOL(     )D(  )AUX( ) 
 
 
 
1)  Data is cleared from the setting field. The cursor is 
also cleared from the screen. 
 
 
(2)  Execution of the manual numeric command ... Execute this after operation (1) above. 
 
 
1)  Press the address key corresponding to the command. The corresponding command value display 
field is highlighted, and the manual numeric command input mode is activated. To execute the tool 
function, input 
 
 
. To execute the miscellaneous function, input 
 
 
 
 
2)  Input the specified numerics from keys. 
  
3) 
Press 
the 
 
 
INPUT 
 key. The command is executed. 
 (Note)  The manual numeric command operation is the same as the operation for the POSITION screen. 
See "2.1.3 Manual numeric Command" in 'POSITION' of 'MONITOR' screen for details. 
 
 
(3)  Returning the mode from manual numeric command to usual data setting 
 
 
Press the 
 
 
 
. The usual data setting 
mode returns. 
T20                      M6 
MG(     )TOOL(     )D(  )AUX( ) 
 
 
 
1)  The cursor is displayed in first parenthesis pairs. 
After this, usual data setting is enabled.