Mitsubishi Electronics 60/60S ユーザーズマニュアル

ページ / 559
4.  Parameters (User) 
4.1  Workpiece Coordinate 
 
 
 
I-135 
4.1.4  Workpiece Coordinate Offset Measurement Function (L System) 
 
 (1) 
Outline 
 
 
The workpiece coordinate offset data is automatically calculated when the tool nose is aligned to the 
workpiece coordinate zero point and the 
 
 
INPUT
 
SHIFT 
 keys (
 
 
CALC 
 key) are pressed. The calculation results 
are displayed in the setting area on the screen. 
 
 (2) 
Operation 
procedures 
 
 
Start
 
(a) Returning to zero point
 
Confirmation of tool length 
and nose wear
 
(b) Selecting the tool
 
(c) Positioning the tool nose
 
Shift to WORK OFFSET screen
 
(d) Selecting the measurement workpiece 
coordinate and axis
 
(e) Automatically calculating the workpiece 
coordinate system's offset data
 
Error?
 
(f) Setting the data
 
Continue 
measurement?
 
End
 
No
Yes 
Yes 
No
No option
 
Setting error
 
Measurement axis R 
point incomplete
 
Compensation number illegal
 
Data range exceeded
 
 
Steps for measuring workpiece coordinate offset (L system)