Mitsubishi Electronics 60/60S ユーザーズマニュアル

ページ / 559
5.  Program 
5.7  Word Editing 
 
 
 
I-222 
5.7.17  Setting the Program Operation Start Position 
 
After setting a program for memory operation, the operation can be started from the designated block in the 
program by designating the starting block. The operation start position in normal word editing is set at the head 
block of that program. To change this start position, move the cursor to the head of the required starting 
position block, and press the 
 
 
INPUT 
 key. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1) The "SEARCH COMPLETE" message 
appears, and operation from the designated 
block is enabled.   
 
 
Press the 
 
 
INPUT 
 key. 
            EDIT 
 
 
                       
 
<EDIT BUFFER> 

                                     
 
 
O12345678 
 
 
N1
 G28 X0 Y0 Z0 ; 
N2 G00 X100.0 ; 
N3 Z100.0 ;          
            EDIT 
 
 
                       
 
<EDIT BUFFER> 

                                     
 
 
O12345678 
 
 
N1 G28 X0 Y0 Z0 ; 
N2
 G00 X100.0 ; 
N3 Z100.0 ;   
                                   
            EDIT 
 
 
                       
 
<EDIT BUFFER> 

                                     
O12345678 
 
 
N1 G28 X0 Y0 Z0 ; 
N2
 G00 X100.0 ; 
N3 Z100.0 ;   
                                   
SEARCH COMPLETE
Move the cursor to the head of the 
required starting position block. 
 
 
 
 
 
 
 
 
 
 
NEXT 
PAGE 
 
 
 
PREVIOUS 
PAGE
 
 
 
 
(Note 1)   If the 
 
 
INPUT 
 key is pressed when the cursor is at a position besides the head of the block, the top of the 
program will be searched. The program will also be displayed from the top. 
(Note 2) 
Up to 96 characters can be key-input in the EDIT BUFFER area.  
 
  
 
 Caution
 
        
 
 
If a block in the program is set as the operation start position is set from a block in the program and the 
program is started, the program before the set block is not executed. If there are coordinate system shift 
commands or M, S, T, and B commands before the block set as the starting position, carry out the required 
commands using the MDI, etc. There is a danger of interference with the machine if the operation is started 
from the set starting position block without carrying out these operations and commands.