Mitsubishi Electronics 60/60S ユーザーズマニュアル

ページ / 559
6.  Data In/Out 
6.1  DATA INPUT 
 
 
 
I-229 
6.1.3  Inputting Tool Offset Data 
 
 
Data which is output by tool offset data output operation can be input. 
 
Data which is created in the same format as output data can be input as tool offset data and workpiece 
coordinate offset data. 
 (Note)  Tool offset data input operation cannot be made during automatic operation. 
 
 
(1)  Inputting tool offset data 
 
Set the data type to tool data. 
#  ( 2 )  DATA  (   ) 
 
 # (  2 ) DATA (      ) 
 
 
 
1)  Paper tape read is initiated. The contents of 
input data and message "DATA IN 
EXECUTION" are displayed. 
2)  When all data to the end has been input and 
the tape end code % (EOR) is read, data input 
ends with message "DATA IN COMPLETE" 
displayed. 
Press the 
 
 
INPUT 
 key. 
<INPUT DATA> 
    G10  L10  P···; 
<COMP. DATA> 
 
 
 
 
DATA IN EXECUTION 
# (  2 ) DATA (      ) 
<INPUT DATA> 
        % 
<COMP. DATA> 
 
 
 
 
DATA IN COMPLETE 
# (    ) DATA (      ) 
 
 
 
 
(2)  When an error occurs during offset tape input: 
 
 
If an error occurs during offset tape input, the error number and error message will be displayed on the 
screen. At this time, input operation stops. (E02, E25, E71, or E86 error) 
 
 
In this case, data input can resume by repressing the 
 
 
INPUT
 key while the input screen is being displayed. 
The data input can resume, beginning with the block next to the erroneous block, which is not input in 
this case.