7.  Diagnosis 
7.4  PLC Interface Diagnosis 
 
 
 
I-286 
7.4.2  PLC Device Data Display 
 
 
Monitor display of state signals and register data used with PLC can be made. 
 
When the PLC-I/F screen is first selected, 8-byte input/output data starting at device X0000 is displayed in 
the left block; 8-byte input/output data starting at device Y0000 is displayed in the right block. 
 
The screen always monitor-displays the PLC signal state. When PLC signal changes, the displayed state 
also changes with the PLC signal change. 
 
However, a lag occurs between PLC signal change and signal display, thus signal display may be delayed 
or a response to a very short signal change may not be made. 
 
(1)  Display device number setting 
 
 
Set the device number in DEVICE (   ). If a different device number or device address is set in the right 
DEVICE (   ), the specified device numbers are displayed in the left and right halves of the screen from 
the display area top to bottom. 
 (Example 
1) 
 
Press the 
 
 
INPUT 
 key. 
Set M0 in left DEVICE (      ) and 
D5 in right DEVICE (      ). 
ALARM SERVO SPINDLE 
PLC-I/F 
MENU 
  DEVICE  DATA 
MODE  DEVICE  DATA  MODE
    (      M0 )    (          )      (    ) 
(    D5    )    (          )      (    )
 [PLC-I/F] 
ALARM/DIAGN 4 
 <SET 
DATA> 
X0008=0001 
Y0015=0000
  
X000A=0001 
D0005=0064
 
 76543210 
HEX   
76543210 
HEX
  M0000 oooooooo 
00 
D0005  oooooooo 
  M0008 ooooo1o1 
05 
  o11oo1oo 
  M0016 oooooooo 
00 
D0006  1oooooo1 
  M0024 o1o1oooo 
50 
  ooooo1oo 
 
 
 
(2)  Device number display change in 8-byte units 
 
 
The current device number display at the top can be changed in 8-byte units by using the 
 
PREVIOUS 
PAGE
 
 
or 
 
 
NEXT 
PAGE 
 key. 
 
 
When the display screen shown in 
(Example 1) appears, press the   
 
 
NEXT 
PAGE 
  key once. 
 [PLC-I/F] 
ALARM/DIAGN 4 
 <SET 
DATA> 
X0008=0001 
Y0015=0000
  
X000A=0001 
D0005=0064
 
 76543210 
HEX   
76543210 
HEX
  M0064 oooooooo 
00 
D0009  o11oo1oo 
64
  M0072 ooooo1o1 
05 
  oooooooo 
00
  M0080 oooooooo 
00 
D0010  1oooooo1 
81
  M0088 o1o1oooo 
50 
  ooooo1oo 
04
 
 
 
 
(3)  When the last device number is exceeded by feeding pages, the data display screen of the last device 
number remains. 
 
(4)  If a number exceeding the preset numbers in specifications or an invalid address is set, a setting error 
results.