Mitsubishi Electronics 60/60S ユーザーズマニュアル
7. Diagnosis
7.5 Absolute Position Monitor
I-291
7.5.2 Absolute Position Initialization
Pressing the menu key
ABS-SRV
displays the ABS SERVO MONITOR screen. When the
NEXT
PAGE
PAGE
key is
pressed on that screen, the ABS POSITION SET screen will display. This screen is used to set the
parameter data used to establish the zero point and to display the initialization.
parameter data used to establish the zero point and to display the initialization.
[ABS POSITION SET]
ALARM/DIAGN 5. 2/2
<X> <Y> <Z> <C>
TYPE
NO-STOPPER
STOPPER NO-STOPPER
STOPPER
STATE
OK
NG
ORIG-RTN
NG
TO END
-12345.678
0.000
1.234
0.000
MACHINE
-12345.678 NOT PASS 0.000
NOT
PASS
#
0 INIT SET
0
1
1
1
1 ORIGIN
0
0
1
0
2 ZERO
-12345.678
0.000
1.234
0.000
#( )
( ) ( )
( ) ( )
ABS-SRV
ADJUST
HISTORY CMPOSIT MENU
Display item
Explanation
TYPE
The position detection system selected by the absolute position
parameter is displayed.
parameter is displayed.
INC.
: Incremental system
DOG
: Dog type absolute position detection
STOPPER
: Dogless absolute position detection machine end
method
NO STOPPER : Dogless absolute position detection marked point
alignment method
STATE
The progress of initialization is displayed, such as "OK" if the absolute
position has been established or "NG" if the absolute position is lost.
position has been established or "NG" if the absolute position is lost.
TO END
The distance between the machine basic position and the first grid point
is displayed.
is displayed.
TO END
Machine basic
position
position
Grid point right before
machine end stopper
machine end stopper
If the first grid point is covered by the grid mask, the distance to the next grid point is
displayed.
displayed.
TO END
Machine basic
position
position
Grid mask
Grid point right before
machine end stopper
machine end stopper
MACHINE
"NOT PASS" is displayed until the machine passes a grid point after
power ON. After the machine passes the grid, the current machine
position is displayed.
power ON. After the machine passes the grid, the current machine
position is displayed.