10.  Ladder Circuit Monitor 
10.1  Parameter Setting 
 
 
 
I-370
 
10.  Ladder Circuit Monitor [for PLC built-in specification only] 
 
 
By pressing the function selection key 
 
 
F0 
, the menu key 
 
 
LADDER
 appears and the sequence circuit 
operation status can be confirmed. 
 
The following monitor functions are available: 
 (1) 
Circuit 
monitor 
 
(2)  Screen stop using a monitor stop trigger point 
 (3) 
Registration 
monitor 
 
(4)  Current value monitoring changeover between decimal notation and hexadecimal notation 
 
 
10.1  Parameter Setting 
 
 
Parameter setting for the ladder circuit monitor function is carried on the PLC parameter BIT SELECT screen. 
 
 
The ladder circuit monitor can be selected by turning the "Onboard valid" parameter ON. 
 
When GX-Developer communication is valid, the on-board screen will not appear and the ladder circuit 
monitor cannot be used. 
 
 
[PLC bit selection] 
7  6 5 4 3 2 1 0 
Bit 
(6451) 
Data 
(0  0 0 1 0 0 0 1) 
1: Onboard valid 
1: GX Developer mode
0: GX Developer communication invalid 
 
 
 
This function is used for user PLC development. 
 