1.  Operation State 
1.1  Operation State Transition Diagram 
 
 
 
II-2 
1.  Operation State 
 
1.1  Operation State Transition Diagram 
 
 
The controller operation state changes momentarily according to the program contents or signals from the 
operation panel or machine. The controller roughly classifies the operation state into power OFF, not ready, 
and ready. 
 
Operation is enabled only in the operating preparation ready state. The operating preparation ready state is 
furthermore classified into reset, automatic operation stop, automatic operation start, and automatic 
operation pause as shown below: 
 
Manual mode operation is enabled in the operation complete state. 
 
 
Block stop 
Input 
Power OFF state
 
1)
Power OFF
2)  Power ON
Operations not ready state
Waiting for READY ON
Failure in operating preparations 
(Emergency stop) 
4)
READY ON
4) Problem is resolved
Operations not ready state
5) 
Reset operations 
In automatic operations 
Automatic operation is 
stopped 
Feed hold 
7) 
6)
Automatic 
operation 
is started 
Automatic operation in 
progress 
6)
8) 
Automatic 
operation 
is started 
Automatic operation is
stopped 
6)
Start
M02/30
Reset process
Reset
5)
Finished
process-
ing 
Automatic 
operation 
not ready 
state 
Resolve problem that 
caused emergency 
stop 
5) 
Reset operations 
CRT operations 
(Machinery preparation) 
Searching unmodal 
Completed
[During operation of the above,
automatic start is not possible.]
3)  Emergency stop
 
 
Operation state transition diagram 
 
1.2  Power OFF 
 
 
The power OFF state means that no power is supplied to the control circuit. 
 
(1)  From any other state to power OFF (transition 1)) 
 
 
• When POWER OFF signal is input from the machine; 
 
 
• When power supplied from the machine to controller is turned OFF; or 
 
 
• When power unit fuse in the controller blows.