8.  Maintenance Functions 
8.1  Data Input/Output Function 
 
 
 
III-57
 
8.  Maintenance Functions 
 
 
The machining programs, parameters and tool data, etc., are saved in the memory. However, these 
contents could be lost due to the battery life, etc. To avoid total loss, save the machining programs, tool data 
and parameters in an input/output device. 
 
 
8.1  Data Input/Output Function 
 
 
The data can be collectively input/output or collated in the data input/output screen. This function can be 
used to protect data and investigate failure causes at the customer premises. It can handle three types of 
data shown below. Hex data is converted and output in the ISO/EIA format. Individual data items can also 
be input/output or collated separately. This function is valid only while the user PLC is halted. 
 
1.  Table data: The data area is reserved in advance. 
 
 
 
Parameter  
(system, common, axis, machine error) 
 
 
 
PLC data (PLC timer, PLC counter, PLC constants, bit selection, ATC data, axis control) 
 
 
 
Work offset data 
 
 
 
Backup data  (PLC latch relay, PLC switch, program No.) 
 
2.  File data: The file format is required before data input. 
 
 
 
Tool offset data 
  
 
Common 
variables 
 
 
 
Tool life control data 
 
3.  PLC program data: PLC program area data 
 
 
 
Ladder 
(ROM: Ladder, message) 
 
 
Screen 
Setting 
Display 
RS-232C device 
Input 
Output 
PLC 
ladder
Tool offset
Common 
variables 
Tool life 
PLC axis 
parameter 
PLC data 
PLC timer,
 PLC 
counter
Backup data 
 
PLC switch, 
latch relay, 
program No. 
R register 
 
PLC constant, 
bit selection, 
ATC data, user 
backup 
Parameter 
table 
System, 
common axis, 
machine error, 
work, offset 
Fixed cycle
program 
Machining 
program 
1
2
3