2.  Monitor 
2.8  LOCAL VARIABLE 
 
 
 
I-75
 
 
Display item 
Explanation 
<INVALID> 
FEED-HOLD 
OVERRIDE 
EXACT 
SNGL-BLOCK 
MST-FIN 
This indicates the modal state of the operation control status by the 
#3003, #3004 command. 
 FEED-HOLD :  Is displayed when command is programmed with 
#3004 bit 0 set to 1, indicating that feed hold is 
invalid. 
 OVERRIDE
:  Is displayed when command is programmed with 
#3004 bit 1 set to 1, indicating that cutting 
override is invalid. 
 EXACT
:  Is displayed when command is programmed with 
#3004 bit 2 set to 1, indicating that the G09 (block 
deceleration check) command is invalid. 
 SNGL-BLOCK:  Is displayed when command is programmed with 
#3003 bit 0 set to 1, indicating that block stop is 
invalid. 
 MST-FIN
:  Is displayed when command is programmed with 
#3003 bit 1 set to 1, indicating the state of 
proceeding to the next block without waiting for 
the M, S, T command completion signal. 
 
 
 
2.8.1  Local Variable Data Display 
 
 
(1)  When local variable #1~#33 command exists in user macro or argument specification is made in user 
macro subprogram call, if the block is executed, the execution result is displayed. 
 
 
 
 
 DISP 
LV. 
(1) 
 ACT. 
LV. 
(0) 
 A 1    0.0000 
 B 2    0.0000 
 C 3    0.0000 
  I  4         
 DISP 
LV. 
(1) 
 ACT. 
LV. 
(1) 
 A 1    1.0000 
 B 2    2.0000 
 C 3    3.0000 
  I  4         
(Example) 
When the following machining 
program is executed and user 
macro subprogram is called, data 
as shown in the right is displayed on
the page of local variable display 
level (1): 
 
G65  P1  A1.  B2.   C3.  ;