Mitsubishi Electronics E70 ユーザーズマニュアル

ページ / 214
4 Connection
MITSUBISHI CNC
102
When connecting to the operation panel I/O unit
Station No. 1, 2, 7, 8 (or 1, 2, 3, 7, 8) are occupied by the operation panel I/O unit. (Station No. 7 and 8 are reserved 
for manual pulse generator.) 
The maximum numbers of stations and I/O points assigned to remote I/O unit(s) via RIO3 are as follows. 
Setting example 1
               Number of occupied stations: 1
                                                                               Total number of occupied stations: 1
Setting example 2
                Number of occupied stations: 2                                             2
                                                       Total number of occupied stations: 4 (Maximum configuration)
Operation panel I/O unit type
Max. number of stations (RIO3 
connection)
Max. number of I/O points 
(RIO3 connection)
Remote I/O
Rotary switch
Setting range
FCU7-DX711
4 stations (No. 3 to 6)
128 points/128 points
2 to 5
FCU7-DX621/721/731
3 stations (No. 4 to 6)
96 points/96 points
3 to 5
2
FCU7-DX711
FCUA-DX101
4
5
2
3
FCU7-DX711
FCUA-DX111
or
FCUA-DX121
FCUA-DX111
or
FCUA-DX121