Mitsubishi Electronics E70 ユーザーズマニュアル

ページ / 214
2 General Specifications
MITSUBISHI CNC
10
2.1 Environment Conditions
(Note 1) "Short term" means within one month. 
(Note 2) For the current value of the I/O circuit, calculate with the number of points used and load. 
(Note 3) For the heating value of the I/O circuit, calculate with the number of points used. 
(Note 4) Allows only the amount to be consumed by control circuit. 
(Note 5) Differs according to the number of machine input operation points and the load and number of points 
connected to the machine output.  The maximum value applies when all points are ON. 
(Note 6) These units, which are open equipments, must be installed within a sealed metal control panel. 
(Note 7) FCU7-KB926 does not need 24VDC power supply input.
Item
Unit name
Control unit
Display unit
Keyboard unit
Operation panel 
I/O unit
Machine operation 
panel
Type
FCU7-MU558
FCU7-DU120-13
FCU7-KB024/025
FCU7-DX621/711/
721/731
FCU7-KB921/926
Gener
al 
specifi
cation
s
Ambient 
temperature
During 
operation
0 to 55C°
During 
storage
-20 to 60C°
Ambient 
humidity
Long 
term
10 to 75% RH (with no dew condensation)
Short 
term
10 to 95% RH (with no dew condensation) (Note 1)
Vibration 
resistance
4.9m/s
2
 or less (during operation)
Shock 
resistance
29.4m/s
2
 or less (during operation)
Working 
atmosphere
No corrosive gases, dust or oil mist
Requir
ed 
power 
specifi
cation
s
Power voltage
24VDC ±5%  
Ripple noise 200mV 
(P-P)
3.3V/12VDC
5VDC
3.3V/5VDC
24VDC ±5%(Note 7)
(Provided by the control unit)
Power capacity
24V  2.5A
-
-
(Note 2)
0.25A(Note 7)
Instantaneous stop 
tolerance time
20ms
-
20ms(min)(Note 7)
Others
Heating 
value
(max.)
12.0W
3.3W
1.0W
Control section: 5.0W 
(Note 3)
6W
Mass
(kg)
1.0
1.5
0.8
0.4
FCU7-KB921:1.2
FCU7-KB926:0.5
Outline 
dimension
(mm)
235(width) x 
173(height) x 
73(depth)
(Depth from the plate 
mounting surface: 60)
260(width) x 
200(height)
140(width) x 200(height)
120(width) x 
180(height)
FCU7-KB921:
260(W) x 140(H)
FCU7-KB926:
140(W) x 140(H)
Item
Unit name
Remote I/O unit
Type
FCUA-DX101
FCUA-DX111
FCUA-DX121
FCUA-DX141
General 
specifications
Ambient temperature
During 
operation
0 to 55C°
During 
storage
-20 to 60C°
Ambient humidity
Long term
10 to 75% RH (with no dew condensation)
Short term
10 to 95% RH (with no dew condensation) (Note 1)
Vibration resistance
4.9m/s
2
 or less (during operation)
Shock resistance
29.4m/s
2
 or less (during operation)
Working atmosphere
No corrosive gases or dust
Required power 
specifications
Input power voltage
24VDC±5% Ripple noise 200mV (P-P)
Power capacity
24V 0.7A (Note 4)
24V 1.5A (Note 4)
24V 0.7A (Note 4)
Instantaneous stop 
tolerance time
-
Others
Heating value
(max.)
25W (Note 5)
30W (Note 5)
30W (Note 5)
Mass
(kg)
0.5
0.6
0.6
0.6