Metrologic Instruments IS1000 ユーザーズマニュアル

ページ / 92
 
 
 
 
 
 
 
IS1000  –  Configuration Guide 
41
START OF CONFIGURATION 
END OF CONFIGURATION 
3.13. Matrix 2/5 
This is a numeric and a more dense code than the Standard 2/5. Each character is 
encoded with three bars and two spaces. It is advised to use it with fixed lengths or with a 
check digit. 
 
3.13.1. Types of Start/Stop 
 
 
 
 
 
 
3.13.2. Check Digit 
 
 
 
 
 
 
 
 
 
The mode Check Digit Not Verified is not advised, missing characters can occur in 
case of incomplete scanning of a code. 
 
3.13.3. Fixed or Variable Lengths 
 
 
 
In case that fixed lengths have been set, go to next page to adjust the number of 
characters per length. 
 WITH 3 BARS * 
WITH 2 BARS 
START STOP 
START
STOP 
 VERIFIED AND TRANSMITTED * 
VERIFIED BUT NOT TRANSMITTED 
NOT VERIFIED 
 VARIABLE * 
FIXED 
!   
Caution: