AR-CF2  TROUBLESHOOTING  8 - 1
[8] TROUBLESHOOTING
Problem
The inserter does not perform at all when the main 
switch of the main unit is turned ON. 
Case1
Cause
Loose contact with the main unit
Check and 
remedy
Check that each connector is firmly 
connected.  
Case2
Cause
Loose contact of the connector terminal of 
the wire (interface harness) connecting 
with the main unit
Check and 
remedy
Check continuity in between the 
connector terminals. Replace the 
connection wire if no continuity is 
measured
Case3
Cause
JAM cover open/close switch fault 
Check and 
remedy
Check continuity between the switch 
contacts., Replace the contacts if no 
continuity is measured.
Case4
Cause
Controller PCB fault 
Check and 
remedy
Check that 24 V DC and 5 V DC are 
supplied from the main unit after the 
above cases 1 to 3 are confirmed. If 24 V 
and 5 V are not present at CN1-2 pin and 
IC5-32 pin on the PCB, replace the 
controller PCB. 
Problem
The paper feed motor does not operate. 
The reverse motor does not operate. 
The horizontal transport motor does not operate. 
Case1
Cause
Loose contact of the motor connector 
terminal
Check and 
remedy
Check continuity of the connector 
contacts.(CN1 to 3) 
Case2
Cause
Disconnection of the motor coil 
Check and 
remedy
Check continuity between the connector 
terminals. Replace the connection wire if 
no continuity is measured.  
Case3
Cause
Controller PCB fault 
Check and 
remedy
If the motor does not operate in the motor 
single operation mode, replace the 
controller PCB. 
Problem
The paper is delivered without being reversed in 
the reverse paper feed mode. 
Case1
Cause
Connector terminal fault of the reverse 
solenoid 
Check and 
remedy
Check continuity of the connector 
contact.(CN4) 
Case2
Cause
Disconnection of the solenoid coil 
Check and 
remedy
Inspect the coil for continuity. Replace the 
coil if no continuity is measured. 
Case3
Cause
Controller PCB fault 
Check and 
remedy
If the solenoid does not perform in the 
solenoid single operation mode, replace 
the controller PCB. 
Problem
Paper jam is displayed on the system display.
Case1
Cause
Paper jam
Check and 
remedy
Visual observation. Take out paper jams.
Case2
Cause Reverse 
sensor 
fault
Check and 
remedy
Measure a voltage of TP2 on the 
controller PCB and check that 3 to 3.6 V 
is observed when no paper is stacked, 
and that 1.5 V or less is observed when 
paper is stacked. Replace the sensor if 
the measured voltage exceeds these 
ranges.
Case3
Cause 
Paper exit sensor fault
Check and 
remedy
Measure a voltage of TP7 on the 
controller PCB and check that 5 V is 
observed when no paper is stacked, and 
that 1 V or less is observed when paper is 
stacked. Replace the sensor if the 
measured voltage exceeds these ranges.
Case4
Cause
 Empty sensor fault
Check and 
remedy
Measure a voltage of TP4 on the 
controller PCB and check that 1 V or less 
is observed when no paper is stacked, 
and that 5 V is observed when paper is 
stacked. Replace the sensor if the 
measured voltage exceeds these ranges.
Case5
Cause
 Registration sensor fault
Check and 
remedy
Measure a voltage of TP5 on the 
controller PCB and check that 5 V is 
observed when no paper is stacked, and 
that 1 V or less is observed when paper is 
stacked. Replace the sensor if the 
measured voltage exceeds these ranges.
Case6
Cause
Timing sensor fault 
Check and 
remedy
Measure a voltage of TP6 on the 
controller PCB and check that a 5 V is 
observed when no paper is stacked, and 
that 1 V or less is observed when paper is 
stacked. Replace the sensor if the 
measured voltage exceeds these ranges.
Case7
Cause
 Controller PCB fault 
Check and 
remedy
If the problem is not solved with the 
sensors whose level changes when each 
is turned ON/OFF, replace the controller 
PCB. 
Problem
The machine does not detect the paper. 
Case1
Cause
Tray sensor fault 
Check and 
remedy
Measure a voltage of TP13 on the 
controller PCB and check thatV is 
observed when no paper is stacked, and 
that 1 V or less is observed when paper is 
stacked. Replace the sensor if the 
measured voltage exceeds these ranges.
Case2
Cause 
Controller PCB fault  
Check and 
remedy
If the problem is not solved with a change 
in the sensor level after the above case 1 
is confirmed, replace the controller PCB.