66
D: Misfeed in the lower paper feed area (AL-1555)
1
Open the lower side cover 
(under the manual tray) and 
remove the misfed paper. If 
 blinks and the misfed 
paper is not seen from the 
area of the lower side cover, 
pull out the lower paper tray 
and remove the misfed 
paper. Then close the lower 
paper tray.
2
Close the lower side cover.
3
Close the side cover by pressing the round projections near 
the side cover open button. The misfeed (
) indicator will go 
out and the start (
) indicator will light up.
E: Misfeed in the SPF (AL-1
553
), RSPF (AL1555)
An original misfeed may occur at one of three locations: if the misfed original is seen 
from the original feeder tray, (A) in the original feeder tray; if the misfed original is not 
seen from the original feeder tray, (B) in the exit area or (C) under the feeding roller. 
Remove the misfed original following the instructions for each location. 
(A) Open the feeding roller cover and pull the original gently to the left and out 
from the original feeder tray. Close the feeding roller cover. Open and close 
the SPF/RSPF to clear the SPF/RSPF misfeed (
) indicator. If the misfed 
original cannot be easily removed, proceed to (C).
When closing the covers, be sure to close the front cover securely and 
then close the side cover. If the covers are closed in the wrong order, the 
covers may be damaged.
Feeding roller cover