Sharp AL2021 ユーザーズマニュアル

ページ / 91
7
66
USER PROGRAMS
The user programs allow the parameters of certain functions to be set, changed, or 
cancelled as desired.
Setting the user programs
1
Press and hold down the light (
) key for more than 5 
seconds until all the alarm indicators (
) blink and 
"
" appears in the display.
2
Use the left copy quantity (
) key to select a user program 
number (For the user program numbers, see the following table.). 
The selected number will blink in the left side of the display.
3
Press the start (
) key. The entered program number will be 
steadily lit and the currently selected parameter number for the 
program will blink on the right side of the display.
4
Select the desired parameter using the right copy quantity (
) key. 
The entered parameter number will blink on the right of the display.
Program 
No.
Mode
Parameters
1
Auto clear time
 10 sec., 2 
 30 sec., *3 
 60 sec.,
 90 sec., 5 
 120 sec., 6 
 OFF
2
Preheat mode
*1 
 30 sec., 2 
 60 sec., 3 
 5 min.,
 30 min., 5 
 60 min., 6 
 120 min.,
 240 min.
3
Auto power shut- off 
mode
*1 
 ON, 2 
 OFF
4
Auto power shut- off 
timer
*1 
 5 min., 2 
 30 min., 3 
 60 min.,
 120 min., 5 
 240 min.
6
SPF automatic 
original discharge 
time (AL-2041)
 5 min., *2 
 30 min.,
 60 min., 4 
 120 min.,
 240 min., 6 
 OFF
10
Resolution of AUTO 
& MANUAL mode
*1 
 300dpi, 2 
 600dpi
13
Memory for printer
 30%, 2 
 40%, *3 
 50%, 
 60%, 5 
 70%
21
Reset factory
 YES, *2 
 NO
22
Sort auto select 
(AL-2041)
*1 
 ON, 2 
 OFF
24
Prevention of OC 
copies when the 
original cover/SPF 
is up function
*1 
 ON, 2 