Sharp JW-20FL5 ユーザーズマニュアル

ページ / 224
6-6
Chapter 6: Connection/Wiring
6
 Wiring the power source
When a 10BASE5 is used, 12 VDC power should be supplied to the transceiver.
Supply power to the 12 VDC power supply input terminal of the Z-336J using a commercial constant
voltage power supply unit.
Remarks
- Use a power supply that is dedicated for use by the Z-336J.
- Do not reverse the positive and negative connections to the power terminals. Reversing the polarity
may damage the Z-336J.
Item
Specifications
Supply voltage
Current capacity
12 VDC 
5%
0.5 A minimum.
(+)(−) 
2
1
O
F
F
  SWA 
ON   
SW1
SW6
ON
S0
S1 
S2 
S3 
S4 
S5 
S6 
S7 
HE 
PE 
 
  T 
12V 
RX 
TX 
LN
Z-336J
12 VDC
* Fuse (0.6 A)
Black wire (-)
Red wire (+)
Twisted pair wires
Case
Green wire 
(ground)
Cable
* Use a fuse that will melt with 
time lag
12 VDC power supply input terminal
(Accessory: Connector, 
cable length 1.5 m)