Sharp JW-20FLT ユーザーズマニュアル

ページ / 224
8-10
Chapter 8: Cyclic Transfer
8
JW30H/J-board (Z-500 series)
address
Top address set in FL-net cyclic
transfer
Byte address
(8)
File address
(8)
Word unit: Octal Word unit: Hex.
File 0
Register
(Possible to register
error history)
E6000, E6001
024000, 024001
012000
1400
to
to
to
to
E7776, E7777
025776, 025777
012777
15FF
TMR/CNT/MD current value
b2000, b2001
026000, 026001
013000
1600
to
to
to
to
b3776, b3777
027776, 027777
013777
17FF
Expansion relay
2000,
2001
030000, 030001
014000
1800
to
to
to
to
7576,
7577
035576, 035577
016677
1DBF
TMR/CNT contact point
7600,
7601
035600, 035601
016700
1DC0
to
to
to
to
7776,
7777
035776, 035777
016777
1DFF
File 1
---
000000, 000001
000000
0000
to
to
to
037776, 037777
017777
1FFF
File 2
---
000000, 000001
000000
0000
to
to
to
177776, 177777
077777
7FFF
File 3
---
000000, 000001
000000
0000
to
to
to
177776, 177777
077777
7FFF
File 10
(H)
---
000000, 000001
000000
0000
to
to
to
177776, 177777
077777
7FFF
to
to
to
to
to
File 14
(H)
---
000000, 000001
000000
0000
to
to
to
177776, 177777
077777
7FFF
to
to
to
to
to
File 2C
(H)
---
000000, 000001
000000
0000
to
to
to
177776, 177777
077777
7FFF
Control module
File memory
JW-31CUH1
File 0
JW-32CUH1 *
File 0, 1, and 2
(File 2 can be allocated to 000000 to 177777 or 000000 to 077777)
JW-33CUH1
File 0, 1 to 3
JW-33CUH2
File 0, 1 to 3 and 10 to 14
(H)
JW-33CUH3
File 0, 1 to 3 and 10 to 2C
(H)
From the previous page
- The relationship between the control module (on which the memory module is installed) and file
memory is as follows.
* File memory of J-board (Z-500 series) is the same as that of JW-32CUH1.