Toshiba e-STUDIO206 ユーザーズマニュアル

ページ / 116
5 TROUBLESHOOTING
96    Before Calling Service Technician
Image trouble
Phenomenon
Usual cause
Countermeasure
The density of the copy 
image is light.
Toner has run out.
The toner lamp blinks when toner has run 
out. Replace the toner cartridge if it is 
blinking.
The copy density is set 
lighter.
Make the density darker if you use the 
manual copy density mode. Or use the 
automatic copy density mode.
The transfer charger wire is 
dirty.
Clean the transfer charger wire.
The density of the copy 
image is dark.
The copy density is set 
darker.
Make the density lighter if you use the 
manual copy density mode. Or use the 
automatic copy density mode.
The copied image is stained.
The Automatic Document 
Feeder (optional) or the 
Platen Cover is not lowered 
fully.
Lower them fully to block outside light.
The original glass, platen 
sheet, scanning area or 
guides are dirty.
Clean them.
The copy density is set 
darker.
Make the density lighter if you use the 
manual copy density mode. Or use the 
automatic copy density mode.
Highly transparent originals 
such as OHP films or tracing 
paper are used.
Place a blank sheet of paper, the same 
size as the original or larger, over the orig-
inal.
The copy image is fogged.
There is a slight gap 
between the original glass 
and the original.
Lower the Platen Cover or the Automatic 
Document Feeder (optional) fully so that 
the original will contact with the original 
glass.
The copy paper is damp.
Replace with dry copy paper.
The density level of the copy 
image is uneven in a horizon-
tal direction.
The transfer charger wire is 
dirty.
Clean the transfer charger wire.
The copy image is partially 
missing.
The size or direction of the 
copy paper and the original, 
or the reproduction ratio is 
not set properly.
Use copy paper of the same size as the 
original or set the reproduction ratio suit-