Citizen CL-E700 Series ユーザーズマニュアル

ページ / 90
85
Appendixes
Parallel Interface (Option)
Specifications
Transmission mode
8-bit parallel data
Receive buffer size
16kB
Transmission modes
Compatible mode:
It is an asynchronous forward direction of the byte 
width (from host to printer) channel, and the interface 
line of the data is operated in accordance with signal 
line definitions of Centronics.
NIBBLE mode:
Nibble mode is asynchronous reverse channel 
communication with data transmission controlled by 
the host computer. In reverse channel transmission, the 
data is nibble transmitted in two parts using four status 
lines (Fault, Select, PE, and Busy). And nibble mode can 
be used along with compatible mode to send data in 
two directions.
ECP mode:
ECP mode permits bi-directional asynchronous data 
transmission, and thanks to its interlock handshake, it 
does not require the timing necessary with compatible 
mode.
Signal level
IEEE1284 standard
Signal line and pin assignment table
Pin No.
Signal name
I/O
Function
1
*STROBE
Input
Strobe signal to read in 8-bit data
2-9
DATA1-8
Input
8-bit parallel signal
10
*ACKNLG
Output
8-bit data request signal
11
BUSY
Output
Signal specifying printer busy
12
PERROR
Output
Signal specifying media out
13
SELECT
Output
Signal specifying if the printer is on-line 
(printing enabled) or off-line (pausing)
14
*AUTOFD
Input
Invalid (ignored)
15
NC
-
Not used
16
GND
-
Signal ground
17
FGND
-
Frame ground
18
P.L.H
Output
Peripheral logic high (pull up to +5 V at 
1.2 kΩ)
19-30
GND
-
Ground for twisted pair return
31
*INIT
Input
Printer reset
32
*FAULT
Output
Signal specifying printer error
33-35
NC
-
Not used
36
*SELECTIN
Input
Invalid (ignored)
Interfaces