Toshiba 310 ユーザーズマニュアル

ページ / 254
FC-210/310  ADJUSTMENT
2 - 10
February 2002  ©  TOSHIBA TEC
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [ENERGY
SAVER] key, immediately after starting the adjustment mode (05), single-sided test copying can be
performed (normal copy mode).
[Procedure for entering adjustment values]
0
1
5
POWER
SET
INTERRUPT
ENERGY
SAVER
Digital keys
START
: Enter codes.
<Operation keys>
<Display>
Varies with the code “XXX” entered with digital keys.
Current adjustment value
Adjustment value newly entered
(If no entering, YYY is displayed.)
Power OFF/ON : Exit the adjustment mode.
Test copy
Digital keys
START
: Enter adjustment
  values.
Value ZZZ is stored
replacing values YYY.
If the test copy does not 
satisfy the specified values,
return to step  1  and 
repeat the adjustment 
procedure.
or
( CLEAR  Use to make corrections)
100%
A
A3
TEST MODE
100%
A
A3
TEST MODE
100%
A
A3
Wait Warming Up
100%
A
A3
COPYING
Code No.
100%
YYY
ZZZ
XXX
A3
TEST MODE