Toshiba e-STUDIO351c ユーザーズマニュアル

ページ / 602
e-STUDIO281c/351c/451c ADJUSTMENT
June 2005 © TOSHIBA TEC
3 - 40
3.6.6
Upper limit value at Toner Saving Mode
The upper limit value is adjusted at the Toner Saving Mode.
<Adjustment Mode (05)>
<Procedure>
Procedure is same as that of “3.6.5 Adjustment of smudged/faint text”.
3.6.7
Dot size adjustment in black printing
The dot size is adjusted in primary scanning direction in black printing.
<Adjustment Mode (05)>
<Procedure>
Procedure is same as that of “3.6.5 Adjustment of smudged/faint text”.
3.6.8
Maximum toner density adjustment to paper type
The maximum toner amount adhering to the paper can be controlled.
<Adjustment Mode (05)>
<Procedure>
Procedure is same as that of “3.6.3 Gamma balance adjustment”.
Note: 
Note: 
The larger the value is, the more frequently fusing offsetting occurs.
3.6.9
Image processing: Gamma correction table all clearing
The state of calibration in color printing mode is initialized at the Setting Mode (08-597). This setting is 
to be performed when a defect occurs in “Automatic gamma adjustment (05-1000 to 1003)”. The cause 
of defect is presumed as an image failure (jittering or uneven image density) at the patch chart for 
gamma adjustment.
Black mode
Language
Remarks
PS
PCL
PS
PS
PCL
PCL
600x600dpi 1200x600dpi 600x600dpi 1200x600dpi
664
665
1055
1056
1057
1058
The smaller the value is, the lighter 
the density of image becomes.
Acceptable values: 0 to 255.
(Default: 176)
Code
Remarks
663
The smaller the value is, the dot size becomes smaller.
Acceptable values: 0 to 255. (Default: 255)
Code
Paper type
Remarks
PS
PCL
1046-0
1046-1
Plain paper
The smaller the value is, the toner amount adhered 
decreases of the high density area (ex. prevention of fusing 
offsetting, etc).
Acceptable values: 0 to 255. (Default: Plain paper: 255, Thick 
paper 1:
255, Thick paper 2: 255, Thick paper 3: 255, OHP film: 200)
1047-0
1047-1
Thick paper 1
1048-0
1048-1
Thick paper 2
1049-0
1049-1
Thick paper 3
1050-0
1050-1
OHP film