Toshiba e-STUDIO351c ユーザーズマニュアル

ページ / 602
e-STUDIO281c/351c/451c ADJUSTMENT
June 2005 © TOSHIBA TEC
3 - 62
Note: 
Note: 
Do not input more than 8 for acceptable value. (If a number from 9 to 255 is input, it is processed 
as 8.)
Relation between adjustment value and changing amount
* CW: Clockwise
CCW: Counter Clockwise
Code to be used for the adjustment
Adjustment mode (05)
Code
Classifi-
cation
Items
Function
Default 
<Accept-
able 
value>
RAM
Contents
Proce-
dure
499
Develop
-ment
Black developer unit 
lift up/down timing 
adjustment
ALL
4
<0-255>
M
Changes the lift up/down 
timing of the black devel-
oper unit when a CEB0 
error occurs.
1
Adjustment 
value
Changing amount for default value
(Turning degree of black developer unit lift up/down lever)
0
Turning 32 degrees CW (approx. 12 mm in the lever circumference)
1
Turning 24 degrees CW (approx. 9 mm in the lever circumference)
2
Turning 16 degrees CW (approx. 6 mm in the lever circumference)
3
Turning 8 degrees CW (approx. 3 mm in the lever circumference)
4
Default value
5
Turning 8 degrees CCW (approx. 3 mm in the lever circumference)
6
Turning 16 degrees CCW (approx. 6 mm in the lever circumference)
7
Turning 24 degrees CCW (approx. 9 mm in the lever circumference)
8
Turning 32 degrees CCW (approx. 12 mm in the lever circumference)