Viewsonic CD5233I ユーザーズマニュアル

ページ / 52
 
 
ViewSonic                                                               
  40                                                                  CD5233 
NOTE 
NOTE 1: IMAGE PERSISTENCE 
Please be aware that LCD Technology may experience a phenomena known as Image Persistence. Image Persistence occurs when 
residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT monitors, LCD monitors’ 
image persistence is not permanent, but constant images being displayed for a long period of time should be avoided. 
To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an 
image was on the monitor for one hour and a residual image remains, the monitor should be turned off for one hour to erase the image. 
As with all personal display devices, ViewSnoic recommends displaying moving images and using a moving panel saving at regular 
intervals whenever the screen is idle or turning off the monitor when not in use. 
 
Please set “POWER SAVE”, “SCREEN SAVER”, “DATE AND TIME” and “SCHEDULE” functions to further reduce the risk of 
Image persistence. 
 
 
For long life use of Public Display
 
 
< Image Sticking of LCD Panel > 
When LCD panel is operated continuously for long hours, a trace of electric charge remains near the electrode inside LCD, and residual 
or “ghost” image of previous image may be observed. (Image Persistence) 
Image Persistence is not permanent, but when fixed image is displayed for long period, ionic impurities inside LCD are accumulated 
along the displayed image, and it is observed permanently. (Image Sticking) 
< Recommendations > 
For preventing the fast transition to Image Sticking, and for longer life usage of LCD, following are recommended. 
1.  Static images should not be displayed for long period. Always use a short cycle to change to other images. 
2.  In case a fixed image is displayed for a long period, it is 
advised
 to activate the MOTION feature that will periodically move the image in 
four directions 
3.  When not in use, please turn off the monitor with your remote control, or use Power Management Function or use the Schedule 
Function of monitor. 
4.  Reducing the environmental temperature will increase the life of your monitor. 
 
When Protection board (glass, acryl) is installed over the LCD surface, enclosed into the box / wall, or stack the monitor, please utilize 
the temperature sensors inside monitor. 
 
To reduce the environmental temperature, the monitor should be set Low Brightness or Cooling Fan “ON” by using Screen sever Function. 
5.  Please use "SCREEN SAVER Mode" of monitor. 
 
 
NOTE 2: HOW TO SETUP SCHEDULE 
Using the “SCHEDULE” function allows you to set up to seven different scheduled time intervals when the LCD Monitor will be 
activated. 
You can select the time the monitor turns on and turns off, the day of week the monitor is activated, and which input source the 
monitor will use for each scheduled activation period. A check mark in the box next to the number of the schedule indicates that the 
selected schedule is in effect. 
To select which schedule to set, use the up/down arrows to move the number (1 to 7) of the schedule. 
Use the (▶) and (◀) buttons to move the cursor horizontally within the particular schedule. Use
 the (   
) and 
(     ) buttons to increase time 
and select input port. The “ENTER” button is used to make a selection. 
If you create a schedule but do not want to use a power on time, select “--” in the “ON” time slot. 
If you do not want to use a power off time select “--” in the OFF time slot. 
If there is no input selected (“--” showing in the input spot) the input from the previous schedule will be used. 
The selection of EVERY DAY within a schedule takes priority over other schedules that are set up to operate weekly. When schedules 
are overlapping, scheduled Power ON time has priority over scheduled Power OFF time. 
If there are two schedules programmed for the same time, then the highest numbered schedule has priority. When the “SLEEP 
TIMER” is set, the “SCHEDULE” function is disabled.