7 Using the MAKE/TRIGGER system
The MAKE/TRIGGER terminal is configured as follows. You can assign a function to each pin terminal in 
“REMOTE SETTING” (
☞ “PIN1, PIN2, PIN3, PIN4, PIN5” on page 15).
•  You cannot change the functions assigned to the pin terminals from 6th to 8th.
Pin No.
Pin name
1
PIN1
2
PIN2
3
PIN3
4
PIN4
5
PIN5
6
PIN6 (TALLY)*
1
7
PIN7 (ENABLE)*
2
8
PIN8 (GND)
*
1
 The 6th pin terminal controls turning on or off the tally lamp (available to control even when the 7th pin terminal is 
invalid).
*
2
 The 7th pin terminal makes the external control valid/invalid. Make sure to control the terminal by the MAKE system.
To assign the functions to the pin terminals
For the operation procedure, see page 7.
1
  Select “REMOTE SETTING” on the SET-UP MENU.
2
 Set 
“PARALLEL 
TYPE” 
to 
“SET.”
3
  Select a pin name (“PIN1” – “PIN5”) for which you want to assign a function, then select the function you want 
to assign.
•  For selectable functions, see the tables on the right.
Operation of the external control
1
  Set “PARALLEL TYPE” of “REMOTE SETTING” to “MAKE” or “TRIGGER” in the SET-UP MENU.
2
  Short-circuit the 7th pin terminal (ENABLE) to the 8th pin terminal (GND) so that the monitor can be controlled 
by the external control.
3
  When the “MAKE” system is selected: Operate each function by short-circuiting the corresponding pin terminal 
to the 8th pin terminal (GND) or opening it.
When the “TRIGGER” system is selected: Operate each function by pulse control, that is short-circuiting the 
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second and opening it.
•  When changing the input with MAKE system, only one pin terminal must be short-circuited. (Other pin terminals 
must be opened.)
•  When selecting the “TRIGGER” system, you can operate only one function at a time. Operate the functions one 
by one.
This is a female terminal.
<Functions controlled by the MAKE/TRIGGER system>
Display
Functions to be controlled
Opening
Short-circuiting
TALLY SEL
Selects the color of the tally lamp.
Green
Red
SDI 1
Changes the input to “SDI 1.”
Invalid
Valid
SDI 2
Changes the input to “SDI 2.”
Invalid
Valid
DVI
Changes the input to “DVI.”
Invalid
Valid
COMP./RGB
Changes the input to “COMPO./RGB.”
Invalid
Valid
VIDEO 1
Changes the input to “VIDEO 1.”
Invalid
Valid
VIDEO 2
Changes the input to “VIDEO 2.”
Invalid
Valid
EXT.SYNC
Changes the sync signal.
Internal sync
External sync
A.MARKER
The area marker indication
Off
On
S.MARKER
The safety marker indication
Off
On
FRAME
Indication of the area of the specified aspect ratio
Off
On
C.MARKER
The center marker indication
Off
On
MARK.SEL
Selects the items of “MARKER”*
3
Non-“R-” items
“R-” items
ASPECT
Changes the aspect ratio.
4:3
16:9
1:1
Displays in 1:1 mode.
Off
On
STATUS
Status display*
4
☞ “On the Status Display” on page 7
L.METER
Audio level meter display
*
5
TIME CODE
Time code display
Off
On
SOURCE ID
☞ “SOURCE ID” on page 15
Off
On
WAVE FORM
Wave form monitor display
Off
On*
6
C.C.
Closed caption display
*
7
COLOR OFF
Color off
Color
Monochrome
SCR CHECK
Screens check
*
8
I/P MODE
Change a mode according to a input picture.
*
9
MUTING
Muting on/off
Off
On
– – –
No function
*
3
 Selects which functions in “MARKER” are activated, non-“R-” items or “R-” items (
 “MARKER”  on page 11).
*
4
 Displays the information shown when INPUT SELECT button of the current input is pressed (
 “On the Status Display” 
on page 7). While controlling with the MAKE system, the information is displayed only at the moment of short-circuiting.
*
5
 While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and hidden 
(opening). When “LEVEL METER ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT” appears). While 
controlling with the TRIGGER system, the pattern of the audio channel display is switched.
*
6
 While controlling with the MAKE system, the wave form monitor will not disappear until opening the terminal 
(regardless of the “AUTO OFF” setting on page 13). 
*
7
 For analog composite signals (NTSC and B/W60 only). While controlling with the MAKE system, the closed caption 
is switched between displayed (short-circuiting) and hidden (opening). When “CLOSED CAPTION” is set to “OFF,” the 
closed caption is not displayed (“NO EFFECT” appears). While controlling with the TRIGGER system, the type of the 
closed caption can be selected.
*
8
 While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue screen 
(short-circuiting). While controlling with the TRIGGER system, the screen changes as same as when pressing 
SCREENS CHECK button (
 page 6).
*
9
 Must be controlled with the TRIGGER system. The mode changes in the order of “NORMAL” 
\ “CINEMA” \ “FIELD”. 
(This function cannot be controlled with the MAKE system.)
•  You cannot assign the same function to different pin terminals.
•  The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and 
opening it.
DT-V24_20L3DY_EN.indb   17
DT-V24_20L3DY_EN.indb   17
08.10.22   3:26:47 PM
08.10.22   3:26:47 PM