IBM 201 ユーザーズマニュアル

ページ / 140
POST error messages
Table 17 provides information about the POST error messages that can appear
during startup.
Note that these diagnostic error messages require the attachment of a monitor,
keyboard, and mouse (before you power on the system) to enable you to see them.
In the following error messages, can be any number or letter.
Table 17. POST error messages
Error
code/Symptom
Meaning
FRU/action
062
Three consecutive boot
failures using the default
configuration
1. Run Configuration/Setup
2. Battery
3. System board
4. Processor
101, 102
System and processor error
System board
106
System and processor error
System board
111
Channel check error
1. Failing ISA Adapter
2. DIMM
3. System board
114
Adapter read-only memory
error
1. Failing Adapter
2. Run Diagnostics
129
Internal cache error
1. Processor
2. Optional processor (if installed)
151
Real-time clock error
1. Run Diagnostics
2. Battery
3. System board
161
Real-time clock battery error
1. Run Configuration/Setup
2. Battery
3. System board
162
Device Configuration error
1. Run Configuration/Setup
Note: Be sure to load the default settings and any
additional desired settings; then, save the configuration.
2. Battery
3. Failing Device
4. System board
163
Real-time clock error
1. Run Configuration/Setup
2. Battery
3. System board
164
Memory configuration
changed
1. Run Configuration/Setup
2. DIMM
175
Hardware error
System board
92