IBM 201 ユーザーズマニュアル
Table 17. POST error messages (continued)
Error
code/Symptom
code/Symptom
Meaning
FRU/action
00019501
Processor 1 is not functioning 1. Check VRM and processor LEDs
2. VRM 1, VRM 2
3. Processor 1
4. Processor board
5. System board
00019502
Processor 2 is not functioning 1. Check VRM and processor LEDs
2. VRM 2
3. Processor 2
4. System board
00019701
Processor 1 failed BIST
1. Processor 1
2. System board
00019702
Processor 2 failed BIST
1. Processor 2
2. System board
00180100
No room for PCI option ROM 1. Run Configuration/Setup
2. Failing adapter
3. System board
00180200
No more I/O space available
for PCI adapter
for PCI adapter
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180300
No more memory (above 1
MB for PCI adapter)
MB for PCI adapter)
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180400
No more memory (below 1
MB for PCI adapter)
MB for PCI adapter)
1. Move the failing adapter to slot 1 or 2
2. Run Configuration/Setup
3. Failing adapter
4. System board
00180500
PCI-option ROM checksum
error
error
1. Remove failing PCI card
2. System board
00180600
PCI built-in self-test failure;
PCI-to PCI-bridge error
PCI-to PCI-bridge error
1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing adapter
4. System board
00180700,
00180800
00180800
General PCI error
1. System board
2. PCI card
01295085
ECC checking hardware test
error
error
Processor
01298001
No update data for processor
1
1
1. Ensure that all processors are the same stepping level
and cache size.
2. Processor 1
96